Size matters: first-in-human study of a novel 4 French REBOA device. Issue 1 (8th January 2021)
- Record Type:
- Journal Article
- Title:
- Size matters: first-in-human study of a novel 4 French REBOA device. Issue 1 (8th January 2021)
- Main Title:
- Size matters: first-in-human study of a novel 4 French REBOA device
- Authors:
- Power, Adam
Parekh, Asha
Scallan, Oonagh
Smith, Shane
Novick, Teresa
Parry, Neil
Moore, Laura - Abstract:
- Abstract : Background: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emerging technique used for non-compressible torso hemorrhage. However, its current use continues to be limited and there is a need for a simple, fast, and low profile REBOA device. Our objective was to evaluate the feasibility of a novel 4 French REBOA device called the COBRA-OS (Control of Bleeding, Resuscitation, Arterial Occlusion System). Methods: This study is the first-in-human feasibility trial of the COBRA-OS. Due to the difficulty of trialing the device in the trauma setting, we performed a feasibility study using organ donors (due to the potential usefulness of the COBRA-OS for normothermic regional perfusion) after neurological determination of death (NDD) prior to organ retrieval. Bilateral 4 French introducer sheaths were placed in both femoral arteries and the COBRA-OS was advanced up the right side and deployed in the thoracic aorta (Zone 1). Once aortic occlusion was confirmed via the left-sided arterial line, the device was deflated, moved to the infrarenal aorta (Zone 3), and redeployed. Results: A total of 7 NDD organ donors were entered into the study, 71% men, with a mean age 46.6 years (range 26 to 64). The COBRA-OS was able to occlude the aorta in Zones 1 and 3 in all patients. The mean time of placing a 4 French sheath was 47.7 seconds (n=13, range 28 to 66 seconds). The mean time from skin to Zone 1 aortic occlusion was 70.1 seconds (range 58 to 105Abstract : Background: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emerging technique used for non-compressible torso hemorrhage. However, its current use continues to be limited and there is a need for a simple, fast, and low profile REBOA device. Our objective was to evaluate the feasibility of a novel 4 French REBOA device called the COBRA-OS (Control of Bleeding, Resuscitation, Arterial Occlusion System). Methods: This study is the first-in-human feasibility trial of the COBRA-OS. Due to the difficulty of trialing the device in the trauma setting, we performed a feasibility study using organ donors (due to the potential usefulness of the COBRA-OS for normothermic regional perfusion) after neurological determination of death (NDD) prior to organ retrieval. Bilateral 4 French introducer sheaths were placed in both femoral arteries and the COBRA-OS was advanced up the right side and deployed in the thoracic aorta (Zone 1). Once aortic occlusion was confirmed via the left-sided arterial line, the device was deflated, moved to the infrarenal aorta (Zone 3), and redeployed. Results: A total of 7 NDD organ donors were entered into the study, 71% men, with a mean age 46.6 years (range 26 to 64). The COBRA-OS was able to occlude the aorta in Zones 1 and 3 in all patients. The mean time of placing a 4 French sheath was 47.7 seconds (n=13, range 28 to 66 seconds). The mean time from skin to Zone 1 aortic occlusion was 70.1 seconds (range 58 to 105 seconds); mean balloon volumes were 15 mL for Zone 1 (range 13 to 20 mL) and 9 mL for Zone 3 (range 6 to 15 mL); there were no complications and visual inspection of the aorta in all patients revealed no injury. Discussion: The COBRA-OS is a novel 4 French REBOA device that has demonstrated fast and safe aortic occlusion in this first-in-human feasibility study. Level of evidence: Level V, therapeutic. … (more)
- Is Part Of:
- Trauma surgery & acute care open. Volume 6:Issue 1(2021)
- Journal:
- Trauma surgery & acute care open
- Issue:
- Volume 6:Issue 1(2021)
- Issue Display:
- Volume 6, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 6
- Issue:
- 1
- Issue Sort Value:
- 2021-0006-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01-08
- Subjects:
- REBOA -- COBRA-OS -- organ donor -- trauma
Traumatology -- Periodicals
Critical care medicine -- Periodicals
Wounds and injuries -- Periodicals
617.1 - Journal URLs:
- http://www.bmj.com/archive ↗
http://tsaco.bmj.com/ ↗ - DOI:
- 10.1136/tsaco-2020-000617 ↗
- Languages:
- English
- ISSNs:
- 2397-5776
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17149.xml