Ex vivo normothermic perfusion for quality assessment of marginal donor kidney transplants. Issue 11 (27th August 2015)
- Record Type:
- Journal Article
- Title:
- Ex vivo normothermic perfusion for quality assessment of marginal donor kidney transplants. Issue 11 (27th August 2015)
- Main Title:
- Ex vivo normothermic perfusion for quality assessment of marginal donor kidney transplants
- Authors:
- Hosgood, S A
Barlow, A D
Hunter, J P
Nicholson, M L - Abstract:
- Abstract: Background: A significant proportion of kidneys procured for transplantation are discarded because of concerns about their suitability. In this study ex vivo normothermic perfusion (EVNP) was used as a quality assessment device before renal transplantation. Methods: Seventy-four human kidneys deemed unsuitable for transplantation following retrieval underwent 60 min of EVNP with an oxygenated red cell-based solution at 36°C. Receiver operating characteristic (ROC) curves were used to identify thresholds of renal blood flow and urine output. These thresholds and a grading of macroscopic appearance were incorporated into an EVNP assessment score (highest quality, 1; lowest, 5). This was applied to a series of 36 kidneys transplanted after EVNP. Results: In the discarded kidney series, 60 (81 per cent) scored 1–4 and 14 (19 per cent) scored 5. Although none of these kidneys was transplanted, those with a score from 1 to 4 were considered suitable for transplantation. In the 36 transplanted kidneys, the score ranged between 1 and 3 (score 1, 17; score 2, 11; score 3, 8). All of these kidneys were transplanted without any complications or primary non-function. The delayed graft function rate was 6 per cent (1 of 17) in kidneys scoring 1, 0 per cent (0 of 11) in those scoring 2 and 38 per cent (3 of 8) in those scoring 3 ( P = 0·024). The mean(s.d.) estimated glomerular filtration rate at 12 months was 51(16), 63(15) and 38(21) ml in kidneys scoring 1, 2 and 3Abstract: Background: A significant proportion of kidneys procured for transplantation are discarded because of concerns about their suitability. In this study ex vivo normothermic perfusion (EVNP) was used as a quality assessment device before renal transplantation. Methods: Seventy-four human kidneys deemed unsuitable for transplantation following retrieval underwent 60 min of EVNP with an oxygenated red cell-based solution at 36°C. Receiver operating characteristic (ROC) curves were used to identify thresholds of renal blood flow and urine output. These thresholds and a grading of macroscopic appearance were incorporated into an EVNP assessment score (highest quality, 1; lowest, 5). This was applied to a series of 36 kidneys transplanted after EVNP. Results: In the discarded kidney series, 60 (81 per cent) scored 1–4 and 14 (19 per cent) scored 5. Although none of these kidneys was transplanted, those with a score from 1 to 4 were considered suitable for transplantation. In the 36 transplanted kidneys, the score ranged between 1 and 3 (score 1, 17; score 2, 11; score 3, 8). All of these kidneys were transplanted without any complications or primary non-function. The delayed graft function rate was 6 per cent (1 of 17) in kidneys scoring 1, 0 per cent (0 of 11) in those scoring 2 and 38 per cent (3 of 8) in those scoring 3 ( P = 0·024). The mean(s.d.) estimated glomerular filtration rate at 12 months was 51(16), 63(15) and 38(21) ml in kidneys scoring 1, 2 and 3 respectively ( P = 0·015). Conclusion: EVNP combined with a simple scoring system is an innovative technology for pretransplant assessment of kidney quality and acceptability for transplantation. This study suggests that a high percentage of retrieved kidneys are being discarded unnecessarily. Abstract : Maximizes kidney use … (more)
- Is Part Of:
- British journal of surgery. Volume 102:Issue 11(2015:Nov.)
- Journal:
- British journal of surgery
- Issue:
- Volume 102:Issue 11(2015:Nov.)
- Issue Display:
- Volume 102, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 102
- Issue:
- 11
- Issue Sort Value:
- 2015-0102-0011-0000
- Page Start:
- 1433
- Page End:
- 1440
- Publication Date:
- 2015-08-27
- Subjects:
- Surgery -- Periodicals
617.005 - Journal URLs:
- http://www.bjs.co.uk/bjsCda/cda/microHome.do ↗
https://academic.oup.com/bjs# ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/bjs.9894 ↗
- Languages:
- English
- ISSNs:
- 0007-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2325.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17168.xml