Detection of advanced colorectal neoplasia and relative colonoscopy workloads using quantitative faecal immunochemical tests: an observational study exploring the effects of simultaneous adjustment of both sample number and test positivity threshold. Issue 1 (29th September 2020)
- Record Type:
- Journal Article
- Title:
- Detection of advanced colorectal neoplasia and relative colonoscopy workloads using quantitative faecal immunochemical tests: an observational study exploring the effects of simultaneous adjustment of both sample number and test positivity threshold. Issue 1 (29th September 2020)
- Main Title:
- Detection of advanced colorectal neoplasia and relative colonoscopy workloads using quantitative faecal immunochemical tests: an observational study exploring the effects of simultaneous adjustment of both sample number and test positivity threshold
- Authors:
- Young, Graeme P
Woodman, Richard J
Symonds, Erin - Abstract:
- Abstract : Objective: When screening for colorectal cancer (CRC) using quantitative faecal immunochemical tests (FIT), test parameters requiring consideration are the faecal haemoglobin concentration (f-Hb) positivity cut-off and the number of stools sampled. This observational study explored variation in f-Hb between samples and the relationship between sensitivity for advanced neoplasia (AN, cancer or advanced adenoma) and colonoscopy workload across a range of independently-adjusted parameter combinations. Design: Quantitative FIT data (OC-Sensor) were accessed from individuals undergoing personalised colonoscopic screening with an offer of 2-sample FIT in the intervening years. We estimated variation in f-Hb between samples in 12 710 completing 2-sample FIT, plus test positivity rates (colonoscopy workload) and sensitivity for AN according to parameter combinations in 4037 instances where FIT was done in the year preceding colonoscopy. Results: There was large within-subject variability between samples, with the ratio for the second to the first sample f-Hb ranging up to 18-fold for all cases, and up to 56-fold for AN cases. Sensitivity for AN was greatest at lower f-Hb cut-offs and/or using 2-sample FIT. Colonoscopy workload varied according to how parameters were combined. Using different cut-offs for 1-sample FIT and 2-sample FIT to return similar sensitivity, workload was less with 2-sample FIT when the sensitivity goal exceeded 35%. Conclusion: Variation in f-HbAbstract : Objective: When screening for colorectal cancer (CRC) using quantitative faecal immunochemical tests (FIT), test parameters requiring consideration are the faecal haemoglobin concentration (f-Hb) positivity cut-off and the number of stools sampled. This observational study explored variation in f-Hb between samples and the relationship between sensitivity for advanced neoplasia (AN, cancer or advanced adenoma) and colonoscopy workload across a range of independently-adjusted parameter combinations. Design: Quantitative FIT data (OC-Sensor) were accessed from individuals undergoing personalised colonoscopic screening with an offer of 2-sample FIT in the intervening years. We estimated variation in f-Hb between samples in 12 710 completing 2-sample FIT, plus test positivity rates (colonoscopy workload) and sensitivity for AN according to parameter combinations in 4037 instances where FIT was done in the year preceding colonoscopy. Results: There was large within-subject variability between samples, with the ratio for the second to the first sample f-Hb ranging up to 18-fold for all cases, and up to 56-fold for AN cases. Sensitivity for AN was greatest at lower f-Hb cut-offs and/or using 2-sample FIT. Colonoscopy workload varied according to how parameters were combined. Using different cut-offs for 1-sample FIT and 2-sample FIT to return similar sensitivity, workload was less with 2-sample FIT when the sensitivity goal exceeded 35%. Conclusion: Variation in f-Hb between samples is such that both parameters are crucial determinants of sensitivity and workload; independent adjustment of each should be considered. The 2-sample FIT approach is best for detecting advanced adenomas as well as CRC provided that the colonoscopy workload is feasible. … (more)
- Is Part Of:
- BMJ open gastroenterology. Volume 7:Issue 1(2020)
- Journal:
- BMJ open gastroenterology
- Issue:
- Volume 7:Issue 1(2020)
- Issue Display:
- Volume 7, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2020-0007-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09-29
- Subjects:
- colorectal cancer screening -- colonoscopy -- gastrointestinal bleeding
Gastroenterology -- Periodicals
616.33005 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopengastro.bmj.com/ ↗ - DOI:
- 10.1136/bmjgast-2020-000517 ↗
- Languages:
- English
- ISSNs:
- 2054-4774
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17046.xml