- Abstract:
- Abstract : Introduction. The use of videolaryngoscopes is recommended for morbidly obese patients. The aim of the study was to evaluate the Levitan FPS optical stylet (Levitan) vs Lafy-Flex videolaryngoscope (Lary-Flex) in a group of MO patients. Methods. Seventy-nine MO (BMI > 40 kg m −2 ) patients scheduled for bariatric surgery were included in the study and randomly allocated to the Levitan FPS or Lary-Flex group. The primary endpoint was time to intubation and evaluation laryngoscopic of glottic view. Anesthesiologists were asked to evaluate the glottic view first under direct laryngoscopy using the videolaryngoscope as a standard laryngoscope (monitor display was excluded from use) and then using devices. The secondary endpoint was the cardiovascular response to intubation and the participant's evaluation of such devices. Results. The time to intubation was 8.57 2.66 sec. versus 5.79 0.2 sec. for Levitan and Lary-Flex, respectively (P < 0.05 ). In all cases of CL grade > 1 under direct laryngoscopy, the study devices improved CL grade to 1. The Levitan FPS produced a greater cardiovascular response than the Lary-Flex videolaryngoscope. Conclusion. The Lary-Flex videolaryngoscope and the Levitan FPS optical stylet improve the laryngeal visualization in morbidly obese patients, allowing for fast endotracheal intubation, but Lary-Flex produces less cardiovascular response to intubation attempt.
- Is Part Of:
- TheScientificWorldjournal. Volume 2014(2014)
- Journal:
- TheScientificWorldjournal
- Issue:
- Volume 2014(2014)
- Issue Display:
- Volume 2014, Issue 2014 (2014)
- Year:
- 2014
- Volume:
- 2014
- Issue:
- 2014
- Issue Sort Value:
- 2014-2014-2014-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-05-20
- Subjects:
- Science -- Periodicals
Technology -- Periodicals
Medicine -- Periodicals
505 - Journal URLs:
- https://www.hindawi.com/journals/tswj/biblio/ ↗
- DOI:
- 10.1155/2014/207591 ↗
- Languages:
- English
- ISSNs:
- 2356-6140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 17101.xml