324 Naturalistic Characterization of Sleep in Chronic Insomnia Using a Non-Contact Sleep Measurement Device. (3rd May 2021)
- Record Type:
- Journal Article
- Title:
- 324 Naturalistic Characterization of Sleep in Chronic Insomnia Using a Non-Contact Sleep Measurement Device. (3rd May 2021)
- Main Title:
- 324 Naturalistic Characterization of Sleep in Chronic Insomnia Using a Non-Contact Sleep Measurement Device
- Authors:
- Hansen, Devon
Peterson, Mary
Raymann, Roy
Van Dongen, Hans
Watson, Nathaniel - Abstract:
- Abstract: Introduction: Individuals with insomnia report poor sleep quality and non-restorative sleep, and often exhibit irregular sleep patterns over days and weeks. First night effects and logistical challenges make it difficult to measure these sleep characteristics in the laboratory. Also, sensitivity to sleep disruption from obtrusive measurement devices confounds sleep measurements in people with insomnia in their naturalistic setting. Non-contact sleep measurement devices have the potential to address these issues and enable ecologically valid, longitudinal characterization of sleep in individuals with insomnia. Here we use a non-contact device – the SleepScore Max (SleepScore Labs) – to assess the sleep of individuals with chronic insomnia, compared to healthy sleeper controls, in their home setting. Methods: As part of a larger study, 13 individuals with chronic insomnia (ages 25-60y, 7 males) and 8 healthy sleeper controls (ages 21-46y, 6 females) participated in an at-home sleep monitoring study. Enrollment criteria included an age range of 18-65y and, for the insomnia group, ICSD-3 criteria for chronic insomnia with no other clinically relevant illness. Participants used the non-contact sleep measurement device to record their sleep periods each night for 8 weeks. Sleep measurements were analyzed for group differences in both means (characterizing sleep overall) and within-subject standard deviations (characterizing sleep variability across nights), usingAbstract: Introduction: Individuals with insomnia report poor sleep quality and non-restorative sleep, and often exhibit irregular sleep patterns over days and weeks. First night effects and logistical challenges make it difficult to measure these sleep characteristics in the laboratory. Also, sensitivity to sleep disruption from obtrusive measurement devices confounds sleep measurements in people with insomnia in their naturalistic setting. Non-contact sleep measurement devices have the potential to address these issues and enable ecologically valid, longitudinal characterization of sleep in individuals with insomnia. Here we use a non-contact device – the SleepScore Max (SleepScore Labs) – to assess the sleep of individuals with chronic insomnia, compared to healthy sleeper controls, in their home setting. Methods: As part of a larger study, 13 individuals with chronic insomnia (ages 25-60y, 7 males) and 8 healthy sleeper controls (ages 21-46y, 6 females) participated in an at-home sleep monitoring study. Enrollment criteria included an age range of 18-65y and, for the insomnia group, ICSD-3 criteria for chronic insomnia with no other clinically relevant illness. Participants used the non-contact sleep measurement device to record their sleep periods each night for 8 weeks. Sleep measurements were analyzed for group differences in both means (characterizing sleep overall) and within-subject standard deviations (characterizing sleep variability across nights), using mixed-effects regression controlling for systematic between-subject differences. Results: Based on the non-contact sleep measurements, individuals with chronic insomnia exhibited greater variability in bedtime, time in bed, total sleep time, sleep latency, total wake time across time in bed, wakefulness after sleep onset, sleep interruptions, and estimated light sleep, compared to healthy sleeper controls (all F>5.7, P<0.05). No significant differences were found for group averages and for variability in estimated deep and REM sleep. Conclusion: In this group of individuals with chronic insomnia, a non-contact device used to characterize sleep naturalistically captured enhanced variability across nights in multiple aspects of sleep stereotypical of sleep disturbances in chronic insomnia, differentiating the sample statistically significantly from healthy sleeper controls. Support (if any): NIH grant KL2TR002317; research devices provided by SleepScore Labs. … (more)
- Is Part Of:
- Sleep. Volume 44(2021)Supplement 2
- Journal:
- Sleep
- Issue:
- Volume 44(2021)Supplement 2
- Issue Display:
- Volume 44, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2021-0044-0002-0000
- Page Start:
- A130
- Page End:
- A130
- Publication Date:
- 2021-05-03
- Subjects:
- Sleep -- Physiological aspects -- Periodicals
Sleep disorders -- Periodicals
Sommeil -- Aspect physiologique -- Périodiques
Sommeil, Troubles du -- Périodiques
Sleep disorders
Sleep -- Physiological aspects
Sleep -- physiological aspects
Sleep Wake Disorders
Psychophysiology
Electronic journals
Periodicals
616.8498 - Journal URLs:
- http://bibpurl.oclc.org/web/21399 ↗
http://www.journalsleep.org/ ↗
https://academic.oup.com/sleep ↗
http://www.oxfordjournals.org/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=369&action=archive ↗ - DOI:
- 10.1093/sleep/zsab072.323 ↗
- Languages:
- English
- ISSNs:
- 0161-8105
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17099.xml