A comparison of valve‐in‐valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves. Issue 6 (27th December 2018)
- Record Type:
- Journal Article
- Title:
- A comparison of valve‐in‐valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves. Issue 6 (27th December 2018)
- Main Title:
- A comparison of valve‐in‐valve transcatheter aortic valve replacement in failed stentless versus stented surgical bioprosthetic aortic valves
- Authors:
- Choi, Charles H.
Cheng, Vivian
Malaver, Diego
Kon, Neal
Kincaid, Edward H.
Gandhi, Sanjay K.
Applegate, Robert J.
Zhao, David X. M. - Abstract:
- Abstract: Objectives: The objectives of this study were to compare short‐ and intermediate‐term clinical outcomes, procedural complications, TAVR prosthesis hemodynamics, and paravalvular leak (PVL) in stentless and stented groups. Background: Valve‐in‐valve (ViV) transcatheter aortic valve replacement (TAVR) is an alternative to surgical redo for bioprosthetic valve failure. There have been limited data on ViV in stentless surgical valves. Methods: We retrospectively analyzed 40 patients who underwent ViV TAVR in prior surgical bioprosthetic valves at Wake Forest Baptist Medical Center from October 2014 to September 2017. Eighty percent (32/40) ViV TAVRs were in stentless, while 20% (8/40) were in stented bioprosthetic valves. Results: The primary mode of bioprosthetic valve failure for ViV implantation in the stentless group was aortic insufficiency (78%, 25/32), while in the stented group was aortic stenosis (75%, 6/8). The ViV procedure success was 96.9% (31/32) in stentless group and 100% in stented group (8/8). There were no significant differences in all‐cause mortality at 30 days between stentless and stented groups (6.9%, 2/31 versus 0%, 0/8, P = 0.33) and at 1 year (0%, 0/25 versus 0%, 0/5). In the stentless group, 34.4% (11/32) required a second valve compared to the stented group of 0% (0/8). There was a significant difference in the mean aortic gradient at 30‐day follow‐up (12.33 ± 6.33 mmHg and 22.63 ± 8.45 mmHg in stentless and stented groups, P < 0.05) andAbstract: Objectives: The objectives of this study were to compare short‐ and intermediate‐term clinical outcomes, procedural complications, TAVR prosthesis hemodynamics, and paravalvular leak (PVL) in stentless and stented groups. Background: Valve‐in‐valve (ViV) transcatheter aortic valve replacement (TAVR) is an alternative to surgical redo for bioprosthetic valve failure. There have been limited data on ViV in stentless surgical valves. Methods: We retrospectively analyzed 40 patients who underwent ViV TAVR in prior surgical bioprosthetic valves at Wake Forest Baptist Medical Center from October 2014 to September 2017. Eighty percent (32/40) ViV TAVRs were in stentless, while 20% (8/40) were in stented bioprosthetic valves. Results: The primary mode of bioprosthetic valve failure for ViV implantation in the stentless group was aortic insufficiency (78%, 25/32), while in the stented group was aortic stenosis (75%, 6/8). The ViV procedure success was 96.9% (31/32) in stentless group and 100% in stented group (8/8). There were no significant differences in all‐cause mortality at 30 days between stentless and stented groups (6.9%, 2/31 versus 0%, 0/8, P = 0.33) and at 1 year (0%, 0/25 versus 0%, 0/5). In the stentless group, 34.4% (11/32) required a second valve compared to the stented group of 0% (0/8). There was a significant difference in the mean aortic gradient at 30‐day follow‐up (12.33 ± 6.33 mmHg and 22.63 ± 8.45 mmHg in stentless and stented groups, P < 0.05) and at 6‐month follow‐up (9.75 ± 5.07 mmHg and 24.00 ± 11.28 mmHg, P < 0.05), respectively. Conclusions: ViV in the stentless bioprosthetic aortic valve has excellent procedural success and intermediate‐term results. Our study shows promising data that may support the application of TAVR in stentless surgical aortic valve. However, further and larger studies need to further validate our single center's experience. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 93:Issue 6(2019)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 93:Issue 6(2019)
- Issue Display:
- Volume 93, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 93
- Issue:
- 6
- Issue Sort Value:
- 2019-0093-0006-0000
- Page Start:
- 1106
- Page End:
- 1115
- Publication Date:
- 2018-12-27
- Subjects:
- aortic valve replacement -- homograft -- stented -- stentless -- transcatheter aortic valve implantation
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28039 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17060.xml