703 From in-lab to at-home: Measuring sleep and memory in the time of SARS-COVID-19. (3rd May 2021)
- Record Type:
- Journal Article
- Title:
- 703 From in-lab to at-home: Measuring sleep and memory in the time of SARS-COVID-19. (3rd May 2021)
- Main Title:
- 703 From in-lab to at-home: Measuring sleep and memory in the time of SARS-COVID-19
- Authors:
- Mullins, Anna
Parekh, Ankit
Kam, Korey
Schoenholz, Reagan
Valencia, Daphne
Roberts, Zachary
Castillo, Bresne
Rapoport, David
Ayappa, Indu
Osorio, Ricardo
Varga, Andrew - Abstract:
- Abstract: Introduction: The SARS-COVID-19 pandemic restricted in-lab research activities especially in older individuals who are considered at-risk for severe disease. To continue longitudinal sleep research in this population we sought to test the feasibility of remotely conducting at-home sleep and memory research and to compare two ambulatory polysomnography (PSG) devices for ongoing home sleep testing. Methods: 20 older (age=65.6±5.5 years) cognitively normal adults (65% female) who had previously undergone 2 nights in-lab sleep, memory and vigilance testing were delivered equipment for 2 nights at-home, technician-guided remote PSG set-up (1 night each for Somté [EEG: Fp1-M2, Cz-M1] and Sleep Profiler (SP) [EEG: Fp1-Fp2] devices- randomized presentation), and 6 timed trials on a 3D spatial maze navigation memory plus morning psychomotor vigilance testing (PVT). The night-to-night differences for devices and in-lab versus at-home testing environments were compared for sleep macro and EEG microarchitecture using paired Wilcoxon rank sum and t-tests where appropriate. First-night maze completion time (CT) and PVT reaction time and lapses were also compared. Results: 19 people completed 2 nights at-home PSG, 18 completed PVT and 9 completed all 6 maze trials. Quality frontal EEG signals were obtained for 16 SP and 11 Somté recordings. There was no significant night to night differences (night 1–night 2) between in-lab and at-home environments for total sleep time (meanAbstract: Introduction: The SARS-COVID-19 pandemic restricted in-lab research activities especially in older individuals who are considered at-risk for severe disease. To continue longitudinal sleep research in this population we sought to test the feasibility of remotely conducting at-home sleep and memory research and to compare two ambulatory polysomnography (PSG) devices for ongoing home sleep testing. Methods: 20 older (age=65.6±5.5 years) cognitively normal adults (65% female) who had previously undergone 2 nights in-lab sleep, memory and vigilance testing were delivered equipment for 2 nights at-home, technician-guided remote PSG set-up (1 night each for Somté [EEG: Fp1-M2, Cz-M1] and Sleep Profiler (SP) [EEG: Fp1-Fp2] devices- randomized presentation), and 6 timed trials on a 3D spatial maze navigation memory plus morning psychomotor vigilance testing (PVT). The night-to-night differences for devices and in-lab versus at-home testing environments were compared for sleep macro and EEG microarchitecture using paired Wilcoxon rank sum and t-tests where appropriate. First-night maze completion time (CT) and PVT reaction time and lapses were also compared. Results: 19 people completed 2 nights at-home PSG, 18 completed PVT and 9 completed all 6 maze trials. Quality frontal EEG signals were obtained for 16 SP and 11 Somté recordings. There was no significant night to night differences (night 1–night 2) between in-lab and at-home environments for total sleep time (mean difference: in-lab= -0.27 vs at-home = 0.35 hours), wake after sleep onset (WASO) (median difference: in-lab= 3.0 vs at-home = 0.7 %WASO), or slow wave sleep (SWS) (mean difference: in-lab= -0.70 vs at-home = 2.3 %SWS). Relative frontal slow wave activity and spindle density were not significantly different between devices or environments. K-complex density (SP= 1.0 vs Somté =2.7/minNREM2, p=0.004) was significantly reduced with the SP device compared to Somté devices. There were no significant differences for maze CT and PVT measures between in-lab and at-home environments. Conclusion: The night-to-night differences in sleep macroarchitecture do not appear to be influenced by environment or device however measures of EEG microstructure such as K-complexes, which are amplitude-dependent, may be underestimated with the Sleep Profiler device due to smaller EEG amplitude from a derivation with short inter-electrode distances. Support (if any): NIH (R01AG056031, R01AG056531, K24) … (more)
- Is Part Of:
- Sleep. Volume 44(2021)Supplement 2
- Journal:
- Sleep
- Issue:
- Volume 44(2021)Supplement 2
- Issue Display:
- Volume 44, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2021-0044-0002-0000
- Page Start:
- A274
- Page End:
- A275
- Publication Date:
- 2021-05-03
- Subjects:
- Sleep -- Physiological aspects -- Periodicals
Sleep disorders -- Periodicals
Sommeil -- Aspect physiologique -- Périodiques
Sommeil, Troubles du -- Périodiques
Sleep disorders
Sleep -- Physiological aspects
Sleep -- physiological aspects
Sleep Wake Disorders
Psychophysiology
Electronic journals
Periodicals
616.8498 - Journal URLs:
- http://bibpurl.oclc.org/web/21399 ↗
http://www.journalsleep.org/ ↗
https://academic.oup.com/sleep ↗
http://www.oxfordjournals.org/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=369&action=archive ↗ - DOI:
- 10.1093/sleep/zsab072.701 ↗
- Languages:
- English
- ISSNs:
- 0161-8105
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17097.xml