Delivery Parameter Variations and Early Clinical Outcomes of Volumetric Modulated Arc Therapy for 31 Prostate Cancer Patients: An Intercomparison of Three Treatment Planning Systems. (15th January 2013)
- Record Type:
- Journal Article
- Title:
- Delivery Parameter Variations and Early Clinical Outcomes of Volumetric Modulated Arc Therapy for 31 Prostate Cancer Patients: An Intercomparison of Three Treatment Planning Systems. (15th January 2013)
- Main Title:
- Delivery Parameter Variations and Early Clinical Outcomes of Volumetric Modulated Arc Therapy for 31 Prostate Cancer Patients: An Intercomparison of Three Treatment Planning Systems
- Authors:
- Tsutsumi, Shinichi
Hosono, Masako N.
Tatsumi, Daisaku
Miki, Yoshitaka
Masuoka, Yutaka
Ogino, Ryo
Ishii, Kentaro
Shimatani, Yasuhiko
Miki, Yukio - Other Names:
- Alaiya Ayodele Academic Editor.
Wang Zhiwei Academic Editor.
Zitzelsberger Horst Academic Editor. - Abstract:
- Abstract : We created volumetric modulated arc therapy (VMAT) plans for 31 prostate cancer patients using one of three treatment planning systems (TPSs)—ERGO++, Monaco, or Pinnacle—and then treated those patients. A dose of 74 Gy was prescribed to the planning target volume (PTV). The rectum, bladder, and femur were chosen as organs at risk (OARs) with specified dose-volume constraints. Dose volume histograms (DVHs), the mean dose rate, the beam-on time, and early treatment outcomes were evaluated and compared. The DVHs calculated for the three TPSs were comparable. The mean dose rates and beam-on times for Ergo++, Monaco, and SmartArc were, respectively, 174.3 ± 17.7, 149.7 ± 8.4, and 185.8 ± 15.6 MU/min and 132.7 ± 8.4, 217.6 ± 13.1, and 127.5 ± 27.1 sec. During a follow-up period of 486.2 ± 289.9 days, local recurrence was not observed, but distant metastasis was observed in a single patient. Adverse events of grade 3 to grade 4 were not observed. The mean dose rate for Monaco was significantly lower than that for ERGO++ and SmartArc (P < 0.0001 ), and the beam-on time for Monaco was significantly longer than that for ERGO++ and SmartArc (P < 0.0001 ). Each TPS was successfully used for prostate VMAT planning without significant differences in early clinical outcomes despite significant TPS-specific delivery parameter variations.
- Is Part Of:
- TheScientificWorldjournal. Volume 2013(2013)
- Journal:
- TheScientificWorldjournal
- Issue:
- Volume 2013(2013)
- Issue Display:
- Volume 2013, Issue 2013 (2013)
- Year:
- 2013
- Volume:
- 2013
- Issue:
- 2013
- Issue Sort Value:
- 2013-2013-2013-0000
- Page Start:
- Page End:
- Publication Date:
- 2013-01-15
- Subjects:
- Science -- Periodicals
Technology -- Periodicals
Medicine -- Periodicals
505 - Journal URLs:
- https://www.hindawi.com/journals/tswj/biblio/ ↗
- DOI:
- 10.1155/2013/289809 ↗
- Languages:
- English
- ISSNs:
- 2356-6140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 17072.xml