Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU. (25th December 2013)
- Record Type:
- Journal Article
- Title:
- Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU. (25th December 2013)
- Main Title:
- Noninvasive Techniques for Blood Pressure Measurement Are Not a Reliable Alternative to Direct Measurement: A Randomized Crossover Trial in ICU
- Authors:
- Ribezzo, Sara
Spina, Eleonora
Di Bartolomeo, Stefano
Sanson, Gianfranco - Other Names:
- Hammarqvist F. Academic Editor.
Kotanidou A. Academic Editor.
Laviolle B. Academic Editor. - Abstract:
- Abstract : Introduction. Noninvasive blood pressure (NIBP) monitoring methods are widely used in critically ill patients despite poor evidence of their accuracy. The erroneous interpretations of blood pressure (BP) may lead to clinical errors. Objectives. To test the accuracy and reliability of aneroid (ABP) and oscillometric (OBP) devices compared to the invasive BP (IBP) monitoring in an ICU population. Materials and Methods. Fifty adult patients (200 comparisons) were included in a randomized crossover trial. BP was recorded simultaneously by IBP and either by ABP or by OBP, taking IBP as gold standard. Results. Compared with ABP, IBP systolic values were significantly higher (mean difference ± standard deviation 9.74 ± 13.8 ; P < 0.0001 ). Both diastolic (- 5.13 ± 7.1 ; P < 0.0001 ) and mean (- 2.14 ± 7.1 ; P = 0.0033 ) IBP were instead lower. Compared with OBP, systolic (10.80 ± 14.9 ; P < 0.0001 ) and mean (5.36 ± 7.1 ; P < 0.0001 ) IBP were higher, while diastolic IBP (- 3.62 ± 6.0 ; P < 0.0001 ) was lower. Bland-Altman plots showed wide limits of agreement in both NIBP-IBP comparisons. Conclusions. BP measurements with different devices produced significantly different results. Since in critically ill patients the importance of BP readings is often crucial, noninvasive techniques cannot be regarded as reliable alternatives to direct measurements.
- Is Part Of:
- TheScientificWorldjournal. Volume 2014(2014)
- Journal:
- TheScientificWorldjournal
- Issue:
- Volume 2014(2014)
- Issue Display:
- Volume 2014, Issue 2014 (2014)
- Year:
- 2014
- Volume:
- 2014
- Issue:
- 2014
- Issue Sort Value:
- 2014-2014-2014-0000
- Page Start:
- Page End:
- Publication Date:
- 2013-12-25
- Subjects:
- Science -- Periodicals
Technology -- Periodicals
Medicine -- Periodicals
505 - Journal URLs:
- https://www.hindawi.com/journals/tswj/biblio/ ↗
- DOI:
- 10.1155/2014/353628 ↗
- Languages:
- English
- ISSNs:
- 2356-6140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 17095.xml