Continuous demagnetisation assessment for triple redundant nine‐phase fault‐tolerant permanent magnet machine. Issue 17 (4th April 2019)
- Record Type:
- Journal Article
- Title:
- Continuous demagnetisation assessment for triple redundant nine‐phase fault‐tolerant permanent magnet machine. Issue 17 (4th April 2019)
- Main Title:
- Continuous demagnetisation assessment for triple redundant nine‐phase fault‐tolerant permanent magnet machine
- Authors:
- Shi, Yanwen
Wang, Jiabin - Abstract:
- Abstract : In this study, the risk of partial irreversible demagnetisation of a triple redundant, nine‐phase fault tolerant machine based on permanent‐magnet‐assisted synchronous reluctance machine topology has been comprehensively assessed under various faults, including the worst case scenario when the applied voltage vector is in the opposite direction of the back electromotive force due to sensing and inverter control failure, by employing a continuous demagnetisation model. The dynamic response during fault transients and the post‐demagnetisation performance, such as the demagnetisation distribution, reduction in the back EMF and torque, will also be analysed and compared.
- Is Part Of:
- Journal of engineering. Volume 2019:Issue 17(2019)
- Journal:
- Journal of engineering
- Issue:
- Volume 2019:Issue 17(2019)
- Issue Display:
- Volume 2019, Issue 17 (2019)
- Year:
- 2019
- Volume:
- 2019
- Issue:
- 17
- Issue Sort Value:
- 2019-2019-0017-0000
- Page Start:
- 4359
- Page End:
- 4363
- Publication Date:
- 2019-04-04
- Subjects:
- machine windings -- machine theory -- permanent magnet motors -- electric potential -- reluctance machines -- permanent magnet machines -- finite element analysis -- fault tolerance -- demagnetisation -- torque
partial irreversible demagnetisation -- nine‐phase fault‐tolerant permanent magnet machine -- continuous demagnetisation assessment -- demagnetisation distribution -- post‐demagnetisation performance -- fault transients -- continuous demagnetisation model -- inverter control failure -- sensing -- applied voltage vector -- worst case scenario -- permanent‐magnet‐assisted synchronous reluctance machine topology -- nine‐phase fault tolerant machine -- triple redundant
Engineering -- Periodicals
Engineering
Electronic journals
Periodicals
620.005 - Journal URLs:
- http://digital-library.theiet.org/content/journals/joe ↗
https://ietresearch.onlinelibrary.wiley.com/journal/20513305 ↗
http://biburl.oclc.org/web/74111 ↗
http://ieeexplore.ieee.org/Xplore/home.jsp ↗ - DOI:
- 10.1049/joe.2018.8177 ↗
- Languages:
- English
- ISSNs:
- 2051-3305
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4978.368000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17085.xml