PM2.5 on the London Underground. (January 2020)
- Record Type:
- Journal Article
- Title:
- PM2.5 on the London Underground. (January 2020)
- Main Title:
- PM2.5 on the London Underground
- Authors:
- Smith, J.D.
Barratt, B.M.
Fuller, G.W.
Kelly, F.J.
Loxham, M.
Nicolosi, E.
Priestman, M.
Tremper, A.H.
Green, D.C. - Abstract:
- Highlights: PM2.5 concentrations on the London Underground are higher than ambient and other subway systems. Dust is generated by the wear of train components and resuspended by passing trains. Variability is caused by ventilation rates and is highest in long underground sections. The differing chemical composition of PM2.5 necessitates calibration of portable instruments. Abstract: Introduction: Despite the London Underground (LU) handling on average 2.8 million passenger journeys per day, the characteristics and potential health effects of the elevated concentrations of metal-rich PM2.5 found in this subway system are not well understood. Methods: Spatial monitoring campaigns were carried out to characterise the health-relevant chemical and physical properties of PM2.5 across the LU network, including diurnal and day-to-day variability and spatial distribution (above ground, depth below ground and subway line). Population-weighted station PM2.5 rankings were produced to understand the relative importance of concentrations at different stations and on different lines. Results: The PM2.5 mass in the LU (mean 88 μg m −3, median 28 μg m −3 ) was greater than at ambient background locations (mean 19 μg m −3, median 14 μg m −3 ) and roadside environments in central London (mean 22 μg m −3, median 14 μg m −3 ). Concentrations varied between lines and locations, with the deepest and shallowest submerged lines being the District (median 4 μg m −3 ) and Victoria (median 361 μg m −3Highlights: PM2.5 concentrations on the London Underground are higher than ambient and other subway systems. Dust is generated by the wear of train components and resuspended by passing trains. Variability is caused by ventilation rates and is highest in long underground sections. The differing chemical composition of PM2.5 necessitates calibration of portable instruments. Abstract: Introduction: Despite the London Underground (LU) handling on average 2.8 million passenger journeys per day, the characteristics and potential health effects of the elevated concentrations of metal-rich PM2.5 found in this subway system are not well understood. Methods: Spatial monitoring campaigns were carried out to characterise the health-relevant chemical and physical properties of PM2.5 across the LU network, including diurnal and day-to-day variability and spatial distribution (above ground, depth below ground and subway line). Population-weighted station PM2.5 rankings were produced to understand the relative importance of concentrations at different stations and on different lines. Results: The PM2.5 mass in the LU (mean 88 μg m −3, median 28 μg m −3 ) was greater than at ambient background locations (mean 19 μg m −3, median 14 μg m −3 ) and roadside environments in central London (mean 22 μg m −3, median 14 μg m −3 ). Concentrations varied between lines and locations, with the deepest and shallowest submerged lines being the District (median 4 μg m −3 ) and Victoria (median 361 μg m −3 but up to 885 μg m −3 ). Broadly in agreement with other subway systems around the world, sampled LU PM2.5 comprised 47% iron oxide, 7% elemental carbon, 11% organic carbon, and 14% metallic and mineral oxides. Although a relationship between line depth and air quality inside the tube trains was evident, there were clear influences relating to the distance from cleaner outside air and the exchange with cabin air when the doors open. The passenger population-weighted exposure analysis demonstrated a method to identify stations that should be prioritised for remediation to improve air quality. Conclusion: PM2.5 concentrations in the LU are many times higher than in other London transport Environments. Failure to include this environment in epidemiological studies of the relationship between PM2.5 and health in London is therefore likely to lead to a large exposure misclassification error. Given the significant contribution of underground PM2.5 to daily exposure, and the differences in composition compared to urban PM2.5, there is a clear need for well-designed studies to better understand the health effects of underground exposure. … (more)
- Is Part Of:
- Environment international. Volume 134(2020)
- Journal:
- Environment international
- Issue:
- Volume 134(2020)
- Issue Display:
- Volume 134, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 134
- Issue:
- 2020
- Issue Sort Value:
- 2020-0134-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- PM2.5 -- Subway -- Exposure -- Composition -- Metro
Environmental protection -- Periodicals
Environmental health -- Periodicals
Environmental monitoring -- Periodicals
Environmental Monitoring -- Periodicals
Environnement -- Protection -- Périodiques
Hygiène du milieu -- Périodiques
Environnement -- Surveillance -- Périodiques
Environmental health
Environmental monitoring
Environmental protection
Periodicals
333.705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01604120 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.envint.2019.105188 ↗
- Languages:
- English
- ISSNs:
- 0160-4120
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.330000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17086.xml