A discrete element model to predict anatomy of the psoas muscle and path of the tendon: Design implications for total hip arthroplasty. (December 2019)
- Record Type:
- Journal Article
- Title:
- A discrete element model to predict anatomy of the psoas muscle and path of the tendon: Design implications for total hip arthroplasty. (December 2019)
- Main Title:
- A discrete element model to predict anatomy of the psoas muscle and path of the tendon: Design implications for total hip arthroplasty
- Authors:
- Audenaert, E.A.
Khanduja, V.
Bauwens, C.
Van Hoof, T.
Pattyn, C.
Steenackers, G. - Abstract:
- Abstract: Background: The accurate estimation of a muscle's line of action is a fundamental requirement in computational modelling. We present a novel anatomical muscle wrapping technique and demonstrate its clinical use on the evaluation of the Psoas muscle mechanics in hip arthroplasty. Methods: A volume preserving, spring model to parameterize muscle anatomy changes during motion is presented. Validation was performed by a CT scan of a cadaver model in multiple positions. The predicted psoas musculotendinous path was compared with the actual imaging findings. In a second stage, psoas kinetics were compared between a conventional versus a resurfacing hip arthroplasty during gait. Findings: Anatomy prediction error was found to be 2.12 mm on average (SD 1.34 mm). When applied to psoas mechanics during walking, the muscle was found to wrap predominantly around the femoral head providing a biomechanically efficient and nearly constant moment arm for flexion during the entire gait cycle. However, this advantage was found to be lost in small diameter hip arthroplasty designs resulting in an important mechanical disadvantage. The moment arm for flexion, was on average 36% (SD 0.03%) lower in the small diameter conventional hip arthroplasty as compared to the large diameter head of the hip resurfacing and this difference was highly significant. ( p < 0.001). Interpretation: Despite the shortcomings of an "in silico" and cadaveric study, our findings are in accordance withAbstract: Background: The accurate estimation of a muscle's line of action is a fundamental requirement in computational modelling. We present a novel anatomical muscle wrapping technique and demonstrate its clinical use on the evaluation of the Psoas muscle mechanics in hip arthroplasty. Methods: A volume preserving, spring model to parameterize muscle anatomy changes during motion is presented. Validation was performed by a CT scan of a cadaver model in multiple positions. The predicted psoas musculotendinous path was compared with the actual imaging findings. In a second stage, psoas kinetics were compared between a conventional versus a resurfacing hip arthroplasty during gait. Findings: Anatomy prediction error was found to be 2.12 mm on average (SD 1.34 mm). When applied to psoas mechanics during walking, the muscle was found to wrap predominantly around the femoral head providing a biomechanically efficient and nearly constant moment arm for flexion during the entire gait cycle. However, this advantage was found to be lost in small diameter hip arthroplasty designs resulting in an important mechanical disadvantage. The moment arm for flexion, was on average 36% (SD 0.03%) lower in the small diameter conventional hip arthroplasty as compared to the large diameter head of the hip resurfacing and this difference was highly significant. ( p < 0.001). Interpretation: Despite the shortcomings of an "in silico" and cadaveric study, our findings are in accordance with previous clinical and gait studies. Furthermore, the findings are strongly in favour of large diameter implant designs, warranting their further development and optimisation. Highlights: A discrete element model for volumetric muscle wrapping of the psoas is presented. Accuracy of anatomy predictions was 2.12 mm (SD 1.34 mm). Small diameter total hip arthroplasty present a significant loss in psoas flexion moment. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 70(2019)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 70(2019)
- Issue Display:
- Volume 70, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 70
- Issue:
- 2019
- Issue Sort Value:
- 2019-0070-2019-0000
- Page Start:
- 186
- Page End:
- 191
- Publication Date:
- 2019-12
- Subjects:
- Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2019.09.004 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17080.xml