Advanced telemonitoring of Left Ventricular Assist Device patients for the early detection of thrombosis. (15th September 2018)
- Record Type:
- Journal Article
- Title:
- Advanced telemonitoring of Left Ventricular Assist Device patients for the early detection of thrombosis. (15th September 2018)
- Main Title:
- Advanced telemonitoring of Left Ventricular Assist Device patients for the early detection of thrombosis
- Authors:
- Glitza, Jenny I.
Müller-von Aschwege, Frerk
Eichelberg, Marco
Reiss, Nils
Schmidt, Thomas
Feldmann, Christina
Wendl, Regina
Schmitto, Jan D.
Hein, Andreas - Abstract:
- Abstract: In modern times, advanced heart failure is a serious issue. Due to a shortage of donor hearts, the implantation of "Left Ventricular Assist Device" (LVAD) as destination therapy has become a common alternative. The LVAD is a mechanical continuous flow pump. However, there are several LVAD complications e.g. a pump thrombosis as a formation of a blood clot inside the LVAD pump. It can result in pump stoppage and lead to death. In order to ensure the success of thrombolytic therapy, it is important to detect a thrombosis early. Since an increase in LVAD power consumption is one indication for a pump thrombosis, this paper shows three algorithms analyzing the LVAD power. These algorithms test absolute and relative threshold and also consider the circadian fluctuation in LVAD power during the day. For the evaluation, a set of 352 LVAD log files including 7 thromboses was used. Compared to the "High Power Alarm", which is a predefined thrombosis alarm of the LVAD controller, these algorithms detect all tested LVAD thrombosis up to 140 h earlier. Nevertheless, the algorithms still cause false alarms (<5%) in patients without an LVAD thrombosis. To reach an earlier and more precise LVAD thrombosis detection, continuous LVAD monitoring is required. Because the LVAD does not provide an interface, an Electrocardiography (ECG) based approach is tested as an alternative monitoring to acquire LVAD data. The LVAD produces an electromagnetical field, whose signal is visible inAbstract: In modern times, advanced heart failure is a serious issue. Due to a shortage of donor hearts, the implantation of "Left Ventricular Assist Device" (LVAD) as destination therapy has become a common alternative. The LVAD is a mechanical continuous flow pump. However, there are several LVAD complications e.g. a pump thrombosis as a formation of a blood clot inside the LVAD pump. It can result in pump stoppage and lead to death. In order to ensure the success of thrombolytic therapy, it is important to detect a thrombosis early. Since an increase in LVAD power consumption is one indication for a pump thrombosis, this paper shows three algorithms analyzing the LVAD power. These algorithms test absolute and relative threshold and also consider the circadian fluctuation in LVAD power during the day. For the evaluation, a set of 352 LVAD log files including 7 thromboses was used. Compared to the "High Power Alarm", which is a predefined thrombosis alarm of the LVAD controller, these algorithms detect all tested LVAD thrombosis up to 140 h earlier. Nevertheless, the algorithms still cause false alarms (<5%) in patients without an LVAD thrombosis. To reach an earlier and more precise LVAD thrombosis detection, continuous LVAD monitoring is required. Because the LVAD does not provide an interface, an Electrocardiography (ECG) based approach is tested as an alternative monitoring to acquire LVAD data. The LVAD produces an electromagnetical field, whose signal is visible in the ECG. It is utilized to calculate the LVAD speed of 9 LVAD patients using the Fast Fourier Transform. An accuracy of 99.8% was achieved. As external events also influence the LVAD measurements, changes in body posture on the LVAD is tested. The results show that the amplitude, measured during supine position, is significantly different to the amplitude measured during sitting and standing. … (more)
- Is Part Of:
- Journal of network and computer applications. Volume 118(2018)
- Journal:
- Journal of network and computer applications
- Issue:
- Volume 118(2018)
- Issue Display:
- Volume 118, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 118
- Issue:
- 2018
- Issue Sort Value:
- 2018-0118-2018-0000
- Page Start:
- 74
- Page End:
- 82
- Publication Date:
- 2018-09-15
- Subjects:
- Left Ventricular Assist Device -- HVAD -- Log files -- ECG -- Pump thrombosis -- Telemonitoring
Microcomputers -- Periodicals
Computer networks -- Periodicals
Application software -- Periodicals
Micro-ordinateurs -- Périodiques
Réseaux d'ordinateurs -- Périodiques
Logiciels d'application -- Périodiques
Application software
Computer networks
Microcomputers
Periodicals
004.05
004 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10848045 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jnca.2018.04.011 ↗
- Languages:
- English
- ISSNs:
- 1084-8045
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5021.410600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17124.xml