A novel protocol to maintain continuous access to thawed plasma at a rural trauma center. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- A novel protocol to maintain continuous access to thawed plasma at a rural trauma center. Issue 1 (January 2020)
- Main Title:
- A novel protocol to maintain continuous access to thawed plasma at a rural trauma center
- Authors:
- Hannigan, Cara
Ologun, Gabriel
Trecartin, Andrew
Colom, Lauren
Bloomdahl, Ry
Seyer, Amanda
LaRock, Lisa
Tubby, Barbara
Cagir, Burt
Granet, Jason
Behm, Robert - Abstract:
- Abstract : BACKGROUND: Early administration of plasma improves mortality in massively transfused patients, but the thawing process causes delay. Small rural centers have been reluctant to maintain thawed plasma due to waste concerns. Our 254-bed rural Level II trauma center initiated a protocol allowing continuous access to thawed plasma, and we hypothesized its implementation would not increase waste or cost. METHODS: Two units of thawed plasma are continuously maintained in the trauma bay blood refrigerator. After 3 days, these units are replaced with freshly thawed plasma and returned to the blood bank for utilization prior to their 5-day expiration date. The blood bank monitors and rotates the plasma. Only trauma surgeons can use the plasma stored in the trauma bay. Wasted units and cost were measured over a 12-month period and compared with the previous 2 years. RESULTS: The blood bank thawed 1127 units of plasma during the study period assigning 274 to the trauma bay. When compared with previous years, we found a significant increase in waste ( p < 0.001) and cost ( p = 0.020) after implementing our protocol. It cost approximately US $125/month extra to maintain continuous access to thawed plasma during the study period. DISCUSSION: A protocol to maintain thawed plasma in the trauma bay at a rural Level II trauma center resulted in a miniscule increase in waste and cost when considering the scope of maintaining a trauma center. We think this cost is also minimal whenAbstract : BACKGROUND: Early administration of plasma improves mortality in massively transfused patients, but the thawing process causes delay. Small rural centers have been reluctant to maintain thawed plasma due to waste concerns. Our 254-bed rural Level II trauma center initiated a protocol allowing continuous access to thawed plasma, and we hypothesized its implementation would not increase waste or cost. METHODS: Two units of thawed plasma are continuously maintained in the trauma bay blood refrigerator. After 3 days, these units are replaced with freshly thawed plasma and returned to the blood bank for utilization prior to their 5-day expiration date. The blood bank monitors and rotates the plasma. Only trauma surgeons can use the plasma stored in the trauma bay. Wasted units and cost were measured over a 12-month period and compared with the previous 2 years. RESULTS: The blood bank thawed 1127 units of plasma during the study period assigning 274 to the trauma bay. When compared with previous years, we found a significant increase in waste ( p < 0.001) and cost ( p = 0.020) after implementing our protocol. It cost approximately US $125/month extra to maintain continuous access to thawed plasma during the study period. DISCUSSION: A protocol to maintain thawed plasma in the trauma bay at a rural Level II trauma center resulted in a miniscule increase in waste and cost when considering the scope of maintaining a trauma center. We think this cost is also minimal when compared with the value of having immediate access to thawed plasma. Constant availability of thawed plasma can be offered at smaller rural centers without a meaningful impact on cost. LEVEL OF EVIDENCE: Economic and Value-based Evaluations, Level III. … (more)
- Is Part Of:
- Journal of trauma and acute care surgery. Volume 88:Issue 1(2020)
- Journal:
- Journal of trauma and acute care surgery
- Issue:
- Volume 88:Issue 1(2020)
- Issue Display:
- Volume 88, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 88
- Issue:
- 1
- Issue Sort Value:
- 2020-0088-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- Fresh frozen plasma -- plasma -- transfusion -- resuscitation -- waste
Surgical intensive care -- Periodicals
Surgical emergencies -- Periodicals
Wounds and injuries -- Surgery -- Periodicals
617.026 - Journal URLs:
- http://journals.lww.com/jtrauma/pages/default.aspx ↗
http://ovidsp.tx.ovid.com/sp-3.5.0b/ovidweb.cgi?&S=NEIKFPIGHGDDBOHLNCALMDIBGLDKAA00&Browse=Toc+Children%7cNO%7cS.sh.2697_1327404888_15.2697_1327404888_27.2697_1327404888_28%7c273%7c50 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/TA.0000000000002472 ↗
- Languages:
- English
- ISSNs:
- 2163-0755
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5070.510500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17053.xml