Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye. Issue 1 (January 2020)
- Main Title:
- Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye
- Authors:
- Paugh, Jerry R.
Tse, June
Nguyen, Tiffany
Sasai, Alan
Chen, Elaine
De Jesus, Melinda Thomas
Kwan, Justin
Nguyen, Andrew Loc
Farid, Marjan
Garg, Sumit
Jester, James V. - Abstract:
- Abstract : Purpose: To examine the effects of volume and method on fluorescein tear breakup time (TBUT) values and to evaluate test efficacy in an independent sample free of selection bias. Methods: Subjects were assessed using a battery of dry eye tests (DETs). Efficacy study: Subjects were randomized to the DET, standard strip, and liquid NaFl on separate days. A masked examiner measured TBUTs from video recordings. Verification study: Subjects were investigated for efficacy using volumes of 5.0 and 2.0 μL mL of NaFl for TBUT. Results: Efficacy study: 46 subjects completed the study. Log-transformed TBUTs were significantly different, normal subjects versus dry subjects, for all 3 methods (all P values < 0.001). Area under the curves (AUCs), cut-points, sensitivity, and specificity were 1) DET: 0.873, 4.4 seconds, 0.97, and 0.67, respectively; 2) 2.0 mL: 0.901, 3.22 seconds, 0.90, and 0.87, respectively; and 3) standard strip: 0.912, 3.42 seconds, 0.97, and 0.80, respectively. Verification study: Data splitting analysis for the 2.0 μL data (n = 174 dry subjects and 97 normal subjects) generated an AUC of 0.917 and a cut-point of 6.05 seconds for a sensitivity of 0.87 and a specificity of 0.81. The 5.0 μL sample yielded an AUC of 0.940, with a sensitivity and specificity of 0.92 and 0.83, respectively, at a cut-point of 5.5 seconds. Conclusions: Little difference in TBUT was found using the 3 clinical methods with video recordings. Analysis using liquid NaFl suggests thatAbstract : Purpose: To examine the effects of volume and method on fluorescein tear breakup time (TBUT) values and to evaluate test efficacy in an independent sample free of selection bias. Methods: Subjects were assessed using a battery of dry eye tests (DETs). Efficacy study: Subjects were randomized to the DET, standard strip, and liquid NaFl on separate days. A masked examiner measured TBUTs from video recordings. Verification study: Subjects were investigated for efficacy using volumes of 5.0 and 2.0 μL mL of NaFl for TBUT. Results: Efficacy study: 46 subjects completed the study. Log-transformed TBUTs were significantly different, normal subjects versus dry subjects, for all 3 methods (all P values < 0.001). Area under the curves (AUCs), cut-points, sensitivity, and specificity were 1) DET: 0.873, 4.4 seconds, 0.97, and 0.67, respectively; 2) 2.0 mL: 0.901, 3.22 seconds, 0.90, and 0.87, respectively; and 3) standard strip: 0.912, 3.42 seconds, 0.97, and 0.80, respectively. Verification study: Data splitting analysis for the 2.0 μL data (n = 174 dry subjects and 97 normal subjects) generated an AUC of 0.917 and a cut-point of 6.05 seconds for a sensitivity of 0.87 and a specificity of 0.81. The 5.0 μL sample yielded an AUC of 0.940, with a sensitivity and specificity of 0.92 and 0.83, respectively, at a cut-point of 5.5 seconds. Conclusions: Little difference in TBUT was found using the 3 clinical methods with video recordings. Analysis using liquid NaFl suggests that the TBUT test has excellent diagnostic accuracy and that a cut-point of 5.3 to 6.0 seconds is the optimum to differentiate normals from persons with dry eye. … (more)
- Is Part Of:
- Cornea. Volume 39:Issue 1(2020)
- Journal:
- Cornea
- Issue:
- Volume 39:Issue 1(2020)
- Issue Display:
- Volume 39, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2020-0039-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- tear breakup time -- fluorescein -- dry eye -- test efficacy
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002148 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17048.xml