Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis: Data From a Nationwide Analysis. Issue 4 (28th January 2020)
- Record Type:
- Journal Article
- Title:
- Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis: Data From a Nationwide Analysis. Issue 4 (28th January 2020)
- Main Title:
- Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis
- Authors:
- Deharo, Pierre
Bisson, Arnaud
Herbert, Julien
Lacour, Thibaud
Saint Etienne, Christophe
Grammatico-Guillon, Leslie
Porto, Alizée
Collart, Frederic
Bourguignon, Thierry
Cuisset, Thomas
Fauchier, Laurent - Abstract:
- Abstract : Background: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices. Methods: Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France. Results: A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10–599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; corrected P =0.005), cardiovascular death (relative risk, 0.82; corrected P =0.002), and rehospitalization for heart failure (relative risk, 0.84; corrected P <0.0001). BE TAVR was also associated with lower ratesAbstract : Background: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices. Methods: Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France. Results: A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10–599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; corrected P =0.005), cardiovascular death (relative risk, 0.82; corrected P =0.002), and rehospitalization for heart failure (relative risk, 0.84; corrected P <0.0001). BE TAVR was also associated with lower rates of pacemaker implantation after the procedure (relative risk, 0.72; corrected P <0.0001). Conclusions: On the basis of the largest cohort available, we observed that Sapien 3 BE valves were associated with lower rates of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation after a TAVR procedure. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 141:Issue 4(2020)
- Journal:
- Circulation
- Issue:
- Volume 141:Issue 4(2020)
- Issue Display:
- Volume 141, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 141
- Issue:
- 4
- Issue Sort Value:
- 2020-0141-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01-28
- Subjects:
- heart valve prosthesis -- transcatheter aortic valve replacement
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.119.043971 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17110.xml