Clinico-hematological and thromboelastographic profiles in glanzmann's thrombasthenia. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Clinico-hematological and thromboelastographic profiles in glanzmann's thrombasthenia. Issue 1 (January 2020)
- Main Title:
- Clinico-hematological and thromboelastographic profiles in glanzmann's thrombasthenia
- Authors:
- Ahammad, Javed
Kamath, Asha
Shastry, Shamee
Chitlur, Meera
Kurien, Annamma - Abstract:
- Abstract : N/A: Glanzmann's thrombasthenia is a rare inherited bleeding disorder characterized by the quantitative or qualitative defect of glycoprotein IIb/IIIa receptor on platelets which leads to ineffective aggregation. Light transmittance aggregometry is considered as the gold standard for diagnosis of Glanzmann's thrombasthenia. Thromboelastography (TEG) is a global hemostatic assay which measures clot formation, clot strengthening and fibrinolysis. This study evaluates the clinical, laboratory and TEG profiles in patients with Glanzmann's thrombasthenia. Bleeding score by (International Society on Thrombosis and Haemostasis) ISTH-bleeding assessment tool (bleeding score), laboratory tests to diagnose Glanzmann's thrombasthenia, and TEG parameters were correlated in 11 Glanzmann's thrombasthenia patients. Seventeen participants with normal bleeding score were included as controls. Bleeding score was increased in all patients. The highest bleeding score was in an adult female (26), whereas the lowest score (4) was in two children of less than 1 year. Majority of TEG parameters (except R -time) showed a statistically significant difference between Glanzmann's thrombasthenia patients and controls ( K -time: P < 0.001, angle: P < 0.001, maximum amplitude: P < 0.001). The average time required to record the maximum amplitude was 23 min. Maximum amplitude was markedly reduced in all Glanzmann's thrombasthenia patients with an average of 20.9 mm (reference range 44–68 mm)Abstract : N/A: Glanzmann's thrombasthenia is a rare inherited bleeding disorder characterized by the quantitative or qualitative defect of glycoprotein IIb/IIIa receptor on platelets which leads to ineffective aggregation. Light transmittance aggregometry is considered as the gold standard for diagnosis of Glanzmann's thrombasthenia. Thromboelastography (TEG) is a global hemostatic assay which measures clot formation, clot strengthening and fibrinolysis. This study evaluates the clinical, laboratory and TEG profiles in patients with Glanzmann's thrombasthenia. Bleeding score by (International Society on Thrombosis and Haemostasis) ISTH-bleeding assessment tool (bleeding score), laboratory tests to diagnose Glanzmann's thrombasthenia, and TEG parameters were correlated in 11 Glanzmann's thrombasthenia patients. Seventeen participants with normal bleeding score were included as controls. Bleeding score was increased in all patients. The highest bleeding score was in an adult female (26), whereas the lowest score (4) was in two children of less than 1 year. Majority of TEG parameters (except R -time) showed a statistically significant difference between Glanzmann's thrombasthenia patients and controls ( K -time: P < 0.001, angle: P < 0.001, maximum amplitude: P < 0.001). The average time required to record the maximum amplitude was 23 min. Maximum amplitude was markedly reduced in all Glanzmann's thrombasthenia patients with an average of 20.9 mm (reference range 44–68 mm) having 100% sensitivity. The thromboelastographic profile of Glanzmann's thrombasthenia showed a consistently reduced maximum amplitude. Hence reduced maximum amplitude with a normal platelet count, significant bleeding score and prolonged bleeding time could potentially be used as a preliminary algorithm for the diagnosis of Glanzmann's thrombasthenia. … (more)
- Is Part Of:
- Blood coagulation and fibrinolysis. Volume 31:Issue 1(2020)
- Journal:
- Blood coagulation and fibrinolysis
- Issue:
- Volume 31:Issue 1(2020)
- Issue Display:
- Volume 31, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 1
- Issue Sort Value:
- 2020-0031-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- bleeding score -- Glanzmann's thrombasthenia -- light transmittance aggregometry -- maximum amplitude -- thromboelastography
Blood -- Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
Blood Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
612.115 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00001721-000000000-00000 ↗
http://www.bloodcoagulation.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBC.0000000000000870 ↗
- Languages:
- English
- ISSNs:
- 0957-5235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2112.650000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17091.xml