Diagnostic Accuracy of Single-shot 2-Dimensional Multisegment Late Gadolinium Enhancement in Ischemic and Nonischemic Cardiomyopathy. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Diagnostic Accuracy of Single-shot 2-Dimensional Multisegment Late Gadolinium Enhancement in Ischemic and Nonischemic Cardiomyopathy. Issue 1 (January 2020)
- Main Title:
- Diagnostic Accuracy of Single-shot 2-Dimensional Multisegment Late Gadolinium Enhancement in Ischemic and Nonischemic Cardiomyopathy
- Authors:
- Muscogiuri, Giuseppe
Gatti, Marco
Dell'Aversana, Serena
Andreini, Daniele
Guaricci, Andrea I.
Guglielmo, Marco
Baggiano, Andrea
Mushtaq, Saima
Conte, Edoardo
Annoni, Andrea
Formenti, Alberto
Mancini, Maria Elisabetta
Gripari, Paola
Rabbat, Mark G.
Pepi, Mauro
Pontone, Gianluca - Abstract:
- Abstract : Purpose: The aim of this study was to assess the reliability of single-shot 2-dimensional multislice late gadolinium enhancement (2D-MSLGE ) compared with gold standard single-slice 2D inversion recovery segmented gradient echo (2D-SSLGE ). Materials and Methods: Sixty-seven patients prospectively underwent clinically indicated cardiac magnetic resonance (CMR) imaging and were enrolled. The image quality was assessed using a 4-point scale. Segments positive for LGE were classified as ischemic or nonischemic for 2D-MSLGE and 2D-SSLGE . Interobserver and intraobserver variability was assessed for both sequences by 2 readers. The endpoints were as follows: (a) detection of myocardial segments involved by LGE and (b) classification of LGE as ischemic and nonischemic pattern. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy value were calculated for the 2 endpoints. Results: 2D-MSLGE and 2D-SSLGE were successfully performed in all patients with comparable image quality (1.56±0.59 vs. 1.54±0.58, P =0.84). For the overall population, 2D-MSLGE correctly identified 1093 of 1139 myocardial segments positive for LGE (96%; 95% confidence interval [CI]: 95%-97%), as compared with 2D-SSLGE . Similarly, 2D-MSLGE correctly identified 1128 of 1139 (99%; 95% CI: 98%-99%) and 1108 of 1139 (97%; 95% CI: 96%-98%) of nonischemic and ischemic LGE patterns. Interobserver and intraobserver variability for quantification of LGE usingAbstract : Purpose: The aim of this study was to assess the reliability of single-shot 2-dimensional multislice late gadolinium enhancement (2D-MSLGE ) compared with gold standard single-slice 2D inversion recovery segmented gradient echo (2D-SSLGE ). Materials and Methods: Sixty-seven patients prospectively underwent clinically indicated cardiac magnetic resonance (CMR) imaging and were enrolled. The image quality was assessed using a 4-point scale. Segments positive for LGE were classified as ischemic or nonischemic for 2D-MSLGE and 2D-SSLGE . Interobserver and intraobserver variability was assessed for both sequences by 2 readers. The endpoints were as follows: (a) detection of myocardial segments involved by LGE and (b) classification of LGE as ischemic and nonischemic pattern. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy value were calculated for the 2 endpoints. Results: 2D-MSLGE and 2D-SSLGE were successfully performed in all patients with comparable image quality (1.56±0.59 vs. 1.54±0.58, P =0.84). For the overall population, 2D-MSLGE correctly identified 1093 of 1139 myocardial segments positive for LGE (96%; 95% confidence interval [CI]: 95%-97%), as compared with 2D-SSLGE . Similarly, 2D-MSLGE correctly identified 1128 of 1139 (99%; 95% CI: 98%-99%) and 1108 of 1139 (97%; 95% CI: 96%-98%) of nonischemic and ischemic LGE patterns. Interobserver and intraobserver variability for quantification of LGE using 2D-MSLGE was 0.98 and 0.99, respectively. The acquisition time was shorter for 2D-MSLGE as compared with 2D-SSLGE (2.0±0.5 vs. 6.0±2.0 min, P : 0.01). Conclusions: As compared with 2D-SSLGE, 2D-MSLGE is a reliable tool in both ischemic and nonischemic cardiac disease; it is associated with shorter scan times without the need for prolonged breath holding and may be beneficial for those with dysrhythmia. … (more)
- Is Part Of:
- Journal of thoracic imaging. Volume 35:Issue 1(2020)
- Journal:
- Journal of thoracic imaging
- Issue:
- Volume 35:Issue 1(2020)
- Issue Display:
- Volume 35, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 35
- Issue:
- 1
- Issue Sort Value:
- 2020-0035-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- late gadolinium enhancement -- tissue characterization -- diagnostic accuracy
Chest -- Radiography -- Periodicals
Chest -- Diseases -- Diagnosis -- Periodicals
617.540757 - Journal URLs:
- http://journals.lww.com/thoracicimaging/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RTI.0000000000000402 ↗
- Languages:
- English
- ISSNs:
- 0883-5993
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.120000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17119.xml