Further studies on the signal enhancement effect in laser diode thermal desorption‐triple quadrupole mass spectrometry using microwell surface coatings. (11th December 2019)
- Record Type:
- Journal Article
- Title:
- Further studies on the signal enhancement effect in laser diode thermal desorption‐triple quadrupole mass spectrometry using microwell surface coatings. (11th December 2019)
- Main Title:
- Further studies on the signal enhancement effect in laser diode thermal desorption‐triple quadrupole mass spectrometry using microwell surface coatings
- Authors:
- Gravel, Alexia
Guérette, Cassandra
Fortin, Daniel
Auger, Serge
Picard, Pierre
Segura, Pedro A. - Abstract:
- Abstract: The laser diode thermal desorption (LDTD) ionization source allows ultrafast and sensitive analysis of small molecules by mass spectrometry. Signal enhancement in LDTD has been observed when coating the surface of sample microwells with a solution of ethylenediaminetetraacetic acid (EDTA) or nitrilotriacetic acid. Here we present a quantitative analysis of signal enhancement using solutions of diverse commercial proteins (lysozyme, immunoglobulin G, albumin, and fibrinogen) as coatings. Results showed that compounds with polar chemical functions such as carboxylic acid, sulfonyl, and nitro had signal enhancement factors, in most cases higher than 10, when using any of the tested proteins as coating agent. Analysis of variance revealed that immunoglobulin G and fibrinogen gave the best results. However, the signal enhancement factors obtained with these proteins were not superior to those observed with EDTA. To explain the signal enhancement effect of proteins, analysis by scanning electron microscopy of dried samples on the microwell sample plates was carried out. Images showed that salicylic acid, one of the compounds with the highest observed signal enhancement, formed a thick layer when applied directly on the uncoated surface, but it formed small crystals (<1 μm) in the presence of protein or EDTA coatings. Further crystallographic studies using powder X‐ray diffraction showed that the crystalline form of salicylic acid is modified in the presence of EDTA.Abstract: The laser diode thermal desorption (LDTD) ionization source allows ultrafast and sensitive analysis of small molecules by mass spectrometry. Signal enhancement in LDTD has been observed when coating the surface of sample microwells with a solution of ethylenediaminetetraacetic acid (EDTA) or nitrilotriacetic acid. Here we present a quantitative analysis of signal enhancement using solutions of diverse commercial proteins (lysozyme, immunoglobulin G, albumin, and fibrinogen) as coatings. Results showed that compounds with polar chemical functions such as carboxylic acid, sulfonyl, and nitro had signal enhancement factors, in most cases higher than 10, when using any of the tested proteins as coating agent. Analysis of variance revealed that immunoglobulin G and fibrinogen gave the best results. However, the signal enhancement factors obtained with these proteins were not superior to those observed with EDTA. To explain the signal enhancement effect of proteins, analysis by scanning electron microscopy of dried samples on the microwell sample plates was carried out. Images showed that salicylic acid, one of the compounds with the highest observed signal enhancement, formed a thick layer when applied directly on the uncoated surface, but it formed small crystals (<1 μm) in the presence of protein or EDTA coatings. Further crystallographic studies using powder X‐ray diffraction showed that the crystalline form of salicylic acid is modified in the presence of EDTA. Salicylic acid when mixed with EDTA had a higher percentage of amorphous phase (38.1%) than without EDTA (23.1%). These results appear to confirm that the diminution of crystal size of analytes and the increase of amorphous phase are implicated in signal enhancement effect observed in LDTD using microwell surface coatings. To design better coatings and completely elucidate the signal enhancement effect in LDTD, more studies are necessary to understand the effects of coatings on the ionization of analytes. … (more)
- Is Part Of:
- Journal of mass spectrometry. Volume 54:Number 12(2019)
- Journal:
- Journal of mass spectrometry
- Issue:
- Volume 54:Number 12(2019)
- Issue Display:
- Volume 54, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 54
- Issue:
- 12
- Issue Sort Value:
- 2019-0054-0012-0000
- Page Start:
- 948
- Page End:
- 956
- Publication Date:
- 2019-12-11
- Subjects:
- high‐throughput -- hormones -- pesticides -- pharmaceuticals -- powder X‐ray diffraction -- proteins -- scanning electron microscopy -- small organic molecules -- stainless steel
Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jms.4455 ↗
- Languages:
- English
- ISSNs:
- 1076-5174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.179500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17057.xml