Procoagulant and platelet‐derived microvesicle absolute counts determined by flow cytometry correlates with a measurement of their functional capacity. Issue 1 (30th September 2014)
- Record Type:
- Journal Article
- Title:
- Procoagulant and platelet‐derived microvesicle absolute counts determined by flow cytometry correlates with a measurement of their functional capacity. Issue 1 (30th September 2014)
- Main Title:
- Procoagulant and platelet‐derived microvesicle absolute counts determined by flow cytometry correlates with a measurement of their functional capacity
- Authors:
- Ayers, Lisa
Harrison, Paul
Kohler, Malcolm
Ferry, Berne - Abstract:
- Abstract : Background: Flow cytometry is the most commonly used technology to measure microvesicles (MVs). Despite reported limitations of this technique, MV levels obtained using conventional flow cytometry have yielded many clinically relevant findings, such as associations with disease severity and ability to predict clinical outcomes. This study aims to determine if MV enumeration by flow cytometry correlates with a measurement of their functional capacity, as this may explain how flow cytometry generates clinically relevant results. Methods: One hundred samples from healthy individuals and patients with obstructive sleep apnoea were analysed by conventional flow cytometry (FACSCalibur) and by three functional MV assays: Zymuphen MP‐activity in which data were given as phosphatidylserine equivalent, STA® Phospholipid Procoag Assay expressed as clotting time and Endogenous Thrombin Potential (ETP) reflecting in vitro thrombin generation. Correlations were determined by Spearman correlation. Results: Absolute counts of lactadherin+ procoagulant MVs generated by flow cytometry weakly correlated with the results obtained from the Zymuphen MP‐activity ( r =0.5370, p <0.0001); correlated with ETP ( r =0.7444, p <0.0001); negatively correlated with STA® Phospholipid Procoag Assay clotting time (−0.7872, p <0.0001), reflecting a positive correlation between clotting activity and flow cytometry. Levels of Annexin V+ procoagulant and platelet‐derived MVs were also associated withAbstract : Background: Flow cytometry is the most commonly used technology to measure microvesicles (MVs). Despite reported limitations of this technique, MV levels obtained using conventional flow cytometry have yielded many clinically relevant findings, such as associations with disease severity and ability to predict clinical outcomes. This study aims to determine if MV enumeration by flow cytometry correlates with a measurement of their functional capacity, as this may explain how flow cytometry generates clinically relevant results. Methods: One hundred samples from healthy individuals and patients with obstructive sleep apnoea were analysed by conventional flow cytometry (FACSCalibur) and by three functional MV assays: Zymuphen MP‐activity in which data were given as phosphatidylserine equivalent, STA® Phospholipid Procoag Assay expressed as clotting time and Endogenous Thrombin Potential (ETP) reflecting in vitro thrombin generation. Correlations were determined by Spearman correlation. Results: Absolute counts of lactadherin+ procoagulant MVs generated by flow cytometry weakly correlated with the results obtained from the Zymuphen MP‐activity ( r =0.5370, p <0.0001); correlated with ETP ( r =0.7444, p <0.0001); negatively correlated with STA® Phospholipid Procoag Assay clotting time (−0.7872, p <0.0001), reflecting a positive correlation between clotting activity and flow cytometry. Levels of Annexin V+ procoagulant and platelet‐derived MVs were also associated with functional assays. Absolute counts of MVs derived from other cell types were not correlated with the functional results. Conclusions: Quantitative results of procoagulant and platelet‐derived MVs from conventional flow cytometry are associated with the functional capability of the MVs, as defined by three functional MV assays. Flow cytometry is a valuable technique for the quantification of MVs from different cellular origins; however, a combination of several analytical techniques may give the most comprehensive information on the role of MVs in health and disease. … (more)
- Is Part Of:
- Journal of extracellular vesicles. Volume 3:Issue 1(2014)
- Journal:
- Journal of extracellular vesicles
- Issue:
- Volume 3:Issue 1(2014)
- Issue Display:
- Volume 3, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2014-0003-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-09-30
- Subjects:
- microvesicles -- conventional flow cytometry -- functional assays -- thrombin generation -- clotting assays
Cells -- Mechanical properties -- Periodicals
Transport Vesicles
Cells -- Mechanical properties
Periodicals
Fulltext
Internet Resources
Periodicals
Electronic journals
Periodicals
571.63 - Journal URLs:
- http://www.ncbi.nlm.nih.gov/pmc/journals/2180/ ↗
https://www.tandfonline.com/toc/zjev20/current ↗
https://onlinelibrary.wiley.com/journal/20013078 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.3402/jev.v3.25348 ↗
- Languages:
- English
- ISSNs:
- 2001-3078
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17106.xml