Implantable cardioverter defibrillators in adult congenital heart disease: long-term follow up of therapies, complications and clinical events. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Implantable cardioverter defibrillators in adult congenital heart disease: long-term follow up of therapies, complications and clinical events. (24th May 2021)
- Main Title:
- Implantable cardioverter defibrillators in adult congenital heart disease: long-term follow up of therapies, complications and clinical events
- Authors:
- Ferreira, V
Cruz Coutinho, M
Portugal, G
Silva Cunha, P
Valente, B
Laranjo, S
Branco Mano, T
Castelo, A
Garcia Bras, P
Cardoso, I
Bras, M
Sousa, L
Oliveira, M - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Introduction: Adults with congenital heart disease (ACHD) at increased risk for sudden cardiac death (SCD) often undergo implantable cardioverter defibrillator (ICD) implantation at young ages. Data evaluating the long-term outcomes of ICD in this population remain scarce. We aimed to characterize the population with ACHD and an ICD. Methods: Consecutive ACHD submitted to an ICD implantation in a single tertiary center were evaluated. Data on baseline clinical features, heart defect, indication for ICD, type of device, ICD-related complication and therapies and mortality during follow-up were collected. Results: A total of 34 patients (P) were evaluated. Median age at implant was 39.3 years (interquartile range [IQR] 29-5-53.6) and median left ventricular ejection fraction (LVEF) was 43.5% (IQR 28.0-53.3). The most common heart defect was tetralogy of Fallot (11P;32, 3%), followed by dextro-transposition of the great arteries, ostium secundum atrial septal defect (ASD) and ventricular septal defect (Figure 1). All P were submitted to surgical correction (median age at surgery 12.5 years [IQR 3.0-29.1]). Sixteen P underwent ICD implantation for primary prevention of SCD, owing to complex cardiopathy and ventricular dysfunction, and 18P due to spontaneous ventricular tachyarrhythmias. The implantable devices were a single-chamber ICD in 55.9%, a double-chamber ICD in 17.6%, a subcutaneous ICD in 20.6% and aAbstract: Funding Acknowledgements: Type of funding sources: None. Introduction: Adults with congenital heart disease (ACHD) at increased risk for sudden cardiac death (SCD) often undergo implantable cardioverter defibrillator (ICD) implantation at young ages. Data evaluating the long-term outcomes of ICD in this population remain scarce. We aimed to characterize the population with ACHD and an ICD. Methods: Consecutive ACHD submitted to an ICD implantation in a single tertiary center were evaluated. Data on baseline clinical features, heart defect, indication for ICD, type of device, ICD-related complication and therapies and mortality during follow-up were collected. Results: A total of 34 patients (P) were evaluated. Median age at implant was 39.3 years (interquartile range [IQR] 29-5-53.6) and median left ventricular ejection fraction (LVEF) was 43.5% (IQR 28.0-53.3). The most common heart defect was tetralogy of Fallot (11P;32, 3%), followed by dextro-transposition of the great arteries, ostium secundum atrial septal defect (ASD) and ventricular septal defect (Figure 1). All P were submitted to surgical correction (median age at surgery 12.5 years [IQR 3.0-29.1]). Sixteen P underwent ICD implantation for primary prevention of SCD, owing to complex cardiopathy and ventricular dysfunction, and 18P due to spontaneous ventricular tachyarrhythmias. The implantable devices were a single-chamber ICD in 55.9%, a double-chamber ICD in 17.6%, a subcutaneous ICD in 20.6% and a CRT-D in 5.9%. During a median follow-up of 4.5 years (IQR 2.1-8.8), 52.9% of the P received appropriate ICD therapies, corresponding to 37.5% and 66.7% of primary and secondary prevention P, respectively. Median time to first arrhythmic event was 25.3 months (IQR 13.7-52.9). Six P (17.6%) suffered ICD-related complications and 20.6% received inappropriate therapies due to supraventricular tachyarrhythmias. During follow-up, 8.8% were submitted to heart transplant and 29.4% died (Table 1). ICD therapies were associated with a composite of death, cardiac transplantation and hospital admission (OR 5.0, 95% CI 1.0-24.3). Conclusion: ACHD with ICD experience high rate of appropriate therapies, including those implanted for primary prevention. The long-term burden of ICD-related complications and inappropriate shocks underlines the need for careful risk stratification and close monitoring. The increased survival of this population justifies collecting data on long-term outcomes to improve its care. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.502 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17096.xml