Glucagon-like peptide-1 directly increases heart rate and shortens atrial refractoriness: an in vivo and ex vivo study in pigs. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Glucagon-like peptide-1 directly increases heart rate and shortens atrial refractoriness: an in vivo and ex vivo study in pigs. (24th May 2021)
- Main Title:
- Glucagon-like peptide-1 directly increases heart rate and shortens atrial refractoriness: an in vivo and ex vivo study in pigs
- Authors:
- Lubberding, AF
Veedfald, S
Sattler, SM
Linz, BM
Eggertsen, CHE
Lilleoer, TMB
Qazi, S
Moeller, C
Tfelt-Hansen, J
Holst, JJ
Jespersen, T - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: Foundation. Main funding source(s): Novo Nordisk Foundation Synergy program Novo Nordisk Foundation Center for Basic Metabolic Research Background: Treatment with glucagon-like peptide-1 receptor agonists (GLP-1 RAs) in patients with type 2 diabetes not only reduces hyperglycaemia, but also improves cardiovascular outcomes. However, GLP-1 RA treatment also increases heart rate: an apparent paradox. Purpose: Whether the heart rate increase is a direct effect, and whether GLP-1 affects other aspects of cardiac electrophysiology, remain unclear. To answer these questions we investigated the effect of GLP-1 infusion on cardiac electrophysiology in vivo and ex vivo in pigs and pig hearts, respectively, during sinus rhythm and pacing. Methods: Anaesthetised pigs (n = 8) received infusions of GLP-1 (10 pmol/kg/min). Electrocardiogram, atrial monophasic action potentials and atrial conduction velocity data were collected and atrial and ventricular effective refractory periods (ERP) were measured. For the ex vivo studies, pig hearts (n = 7) were excised, retrogradely perfused and exposed to consecutive bolus perfusions of 2 and 4 nmol GLP-1, 100 nmol of the GLP-1 receptor antagonist exendin-9-39 and a final 4 nmol bolus of GLP-1. The same electrophysiological parameters were measured. Results: In anaesthetised pigs, GLP-1 increased heart rate, cardiac output and diastolic pressure, while systemic vascular resistance wasAbstract: Funding Acknowledgements: Type of funding sources: Foundation. Main funding source(s): Novo Nordisk Foundation Synergy program Novo Nordisk Foundation Center for Basic Metabolic Research Background: Treatment with glucagon-like peptide-1 receptor agonists (GLP-1 RAs) in patients with type 2 diabetes not only reduces hyperglycaemia, but also improves cardiovascular outcomes. However, GLP-1 RA treatment also increases heart rate: an apparent paradox. Purpose: Whether the heart rate increase is a direct effect, and whether GLP-1 affects other aspects of cardiac electrophysiology, remain unclear. To answer these questions we investigated the effect of GLP-1 infusion on cardiac electrophysiology in vivo and ex vivo in pigs and pig hearts, respectively, during sinus rhythm and pacing. Methods: Anaesthetised pigs (n = 8) received infusions of GLP-1 (10 pmol/kg/min). Electrocardiogram, atrial monophasic action potentials and atrial conduction velocity data were collected and atrial and ventricular effective refractory periods (ERP) were measured. For the ex vivo studies, pig hearts (n = 7) were excised, retrogradely perfused and exposed to consecutive bolus perfusions of 2 and 4 nmol GLP-1, 100 nmol of the GLP-1 receptor antagonist exendin-9-39 and a final 4 nmol bolus of GLP-1. The same electrophysiological parameters were measured. Results: In anaesthetised pigs, GLP-1 increased heart rate, cardiac output and diastolic pressure, while systemic vascular resistance was decreased. Infusion of GLP-1 decreased PQ interval in sinus rhythm (P = 0.019, n = 8) and during atrial pacing (P = 0.027, n = 6) with 8 ± 3 % and 12 ± 3 %, respectively. Additionally, GLP-1 decreased atrial ERP at all pacing cycle lengths (P = 0.04, n = 7), while ventricular ERP was unaffected (P = 0.29, n = 7). In the isolated perfused heart, GLP-1 increased heart rate with 13 ± 2 bpm (P = 0.001, n = 7). This increase in heart rate was completely abolished by pre-administration of exendin-9-39. Atrial ERP shortened after GLP-1 perfusion (P = 0.01, n = 7) comparable to the in vivo studies, with an average decrease of 11 ± 2 %. This effect was also abolished by exendin-9-39. Conclusion: GLP-1 increases heart rate through activation of the GLP-1 receptor in the isolated perfused heart, suggesting a direct effect of GLP-1 rather than activation through the central nervous system. Additionally, GLP-1 affects atrial electrophysiology, but not ventricular electrophysiology, in vivo and ex vivo independent of the increase in heart rate. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.576 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17094.xml