Slow VT treatment in a contemporary population of primary prevention ICD recipients. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Slow VT treatment in a contemporary population of primary prevention ICD recipients. (24th May 2021)
- Main Title:
- Slow VT treatment in a contemporary population of primary prevention ICD recipients
- Authors:
- Angeletti, A
Ziacchi, M
Martignani, C
Massaro, M
Statuto, G
Sorrentino, S
Piemontese, GP
Capobianco, C
Spadotto, A
Minguzzi, A
Diemberger, I
Biffi, M - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Implantable cardioverter defibrillator (ICD) is an effective therapy for sudden cardiac death (SCD). 2015 HRS/EHRA/APHRS/SOLAECE expert consensus document suggests long VT detection, above 185 bpm, as optimal ICD programming to reduce unnecessary therapies in primary prevention (PP). Purpose: The aim of our study is to evaluate incidence, safety and efficacy of ICD treatment for VT arrhythmias below 185 bpm, in a contemporary population of PP ICD recipients with long detection intervals (LDI), morphological discrimination algorithm and antitachycardia pacing therapies (ATP) before shock. Methods: We conducted a single centre retrospective study enrolling 236 patients implanted with a primary-prevention indication from January 2013 to June 2019. Patients were implanted with single or dual chamber single-lead transvenous ICD. All patients had standard device setting with long (at least 20 s in VT and 7 s in VF) VT/VF detection above 150 bpm and therapies starting from 171 with up to 5 ATP and multiple shocks. PainFREE-like bursts and Schaumann-like ramps ATP were always set in VT zone. Of each patient we collected a detailed report of up to five appropriate events and three inappropriate events. Arrhythmia diagnosis was confirmed from 3 independent expert physicians. Date of the event, cycle length, type of morphology (polymorphic or monomorphic), therapies with their effect were collected.Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Implantable cardioverter defibrillator (ICD) is an effective therapy for sudden cardiac death (SCD). 2015 HRS/EHRA/APHRS/SOLAECE expert consensus document suggests long VT detection, above 185 bpm, as optimal ICD programming to reduce unnecessary therapies in primary prevention (PP). Purpose: The aim of our study is to evaluate incidence, safety and efficacy of ICD treatment for VT arrhythmias below 185 bpm, in a contemporary population of PP ICD recipients with long detection intervals (LDI), morphological discrimination algorithm and antitachycardia pacing therapies (ATP) before shock. Methods: We conducted a single centre retrospective study enrolling 236 patients implanted with a primary-prevention indication from January 2013 to June 2019. Patients were implanted with single or dual chamber single-lead transvenous ICD. All patients had standard device setting with long (at least 20 s in VT and 7 s in VF) VT/VF detection above 150 bpm and therapies starting from 171 with up to 5 ATP and multiple shocks. PainFREE-like bursts and Schaumann-like ramps ATP were always set in VT zone. Of each patient we collected a detailed report of up to five appropriate events and three inappropriate events. Arrhythmia diagnosis was confirmed from 3 independent expert physicians. Date of the event, cycle length, type of morphology (polymorphic or monomorphic), therapies with their effect were collected. Results: During a mean follow-up of 42 months, 47 (20 %) and 18 (8%) patients had at least one appropriate and inappropriate activation, respectively. The detailed-events analysis shows that 16 (7%) patients had 38 (30%) appropriate events with rate <188 bpm. At these rate ATP were 97% effective. 14 (38%) of inappropriate activations were caused by arrythmias with ventricular rate below 188 bpm and half of these received a shock; 30% of inappropriate shocks were due to arrhythmia with rate <188 bpm. 73% of treated events, with rate <188 bpm, were appropriate. Only 5.6% (n = 10) of ATP attempts cause arrhythmia acceleration. Conclusions: One third of detected arrhythmias had a rate below 188 bpm and 73% were true VT. In this slow VT zone, ATP had a high success rate with low percentage of acceleration. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.411 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17093.xml