Prognostic impact of subcutaneous implantable cardioverter-defibrillator appropriate and inappropriate shocks. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Prognostic impact of subcutaneous implantable cardioverter-defibrillator appropriate and inappropriate shocks. (24th May 2021)
- Main Title:
- Prognostic impact of subcutaneous implantable cardioverter-defibrillator appropriate and inappropriate shocks
- Authors:
- Oliveira, L
Cavaco, D
Rodrigues, G
Matos, D
Carvalho, MS
Carmo, J
Santos, PG
Costa, F
Carmo, P
Santos, I
Morgado, F
Mendes, M
Adragao, P - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Previous studies have shown an adverse prognosis for patients with transvenous implantable cardioverter-defibrillators (ICD) who receive both appropriate and inappropriate shocks. There is a paucity of data regarding the prognosis of inappropriate shocks in patients with a subcutaneous ICD (S-ICD). Purpose: To assess and characterize S-ICD appropriate (AS) and inappropriate shocks (IAS) and their impact on mortality. Methods: Single center observational registry of 162 consecutive patients who underwent S-ICD implantation for primary and secondary prevention between November 2009 and September 2020. Only follow-up data of at least 6 months was analysed to identify predictors of both IAS and AS and their mortality impact. Results: A total of 144 patients were included in the analysis. Mean age was 42.2 ± 16.6 years and 75% of the patients were male. One hundred and four patients (72.2%) implanted the S-ICD in primary prevention. The most common etiology was ischemic cardiomyopathy (22.9%) followed by hypertrophic cardiomyopathy (18.8%) and dilated idiopathic cardiomyopathy (14.6%). During a mean follow-up of 42.3 ± 29.9 months a total of 48 patients (33.3%) experienced at least one S-ICD shock. Twenty-nine (20.1%) patients received AS due to VT/VF and 31 patients (21.5%) received IAS. Eighteen (58.1%) of the IAS were due to oversensing/noise/discrimination errors and the remaining due toAbstract: Funding Acknowledgements: Type of funding sources: None. Background: Previous studies have shown an adverse prognosis for patients with transvenous implantable cardioverter-defibrillators (ICD) who receive both appropriate and inappropriate shocks. There is a paucity of data regarding the prognosis of inappropriate shocks in patients with a subcutaneous ICD (S-ICD). Purpose: To assess and characterize S-ICD appropriate (AS) and inappropriate shocks (IAS) and their impact on mortality. Methods: Single center observational registry of 162 consecutive patients who underwent S-ICD implantation for primary and secondary prevention between November 2009 and September 2020. Only follow-up data of at least 6 months was analysed to identify predictors of both IAS and AS and their mortality impact. Results: A total of 144 patients were included in the analysis. Mean age was 42.2 ± 16.6 years and 75% of the patients were male. One hundred and four patients (72.2%) implanted the S-ICD in primary prevention. The most common etiology was ischemic cardiomyopathy (22.9%) followed by hypertrophic cardiomyopathy (18.8%) and dilated idiopathic cardiomyopathy (14.6%). During a mean follow-up of 42.3 ± 29.9 months a total of 48 patients (33.3%) experienced at least one S-ICD shock. Twenty-nine (20.1%) patients received AS due to VT/VF and 31 patients (21.5%) received IAS. Eighteen (58.1%) of the IAS were due to oversensing/noise/discrimination errors and the remaining due to supraventricular tachycardia. Overall, patients with AS (HR 4.93, 95% CI 1.58-15.36, p = 0.006) and higher number of total AS (HR 1.10, 95% CI 1.00-1.20, p = 0.044) were associated with higher mortality during follow-up. S-ICD IAS therapy did not affect overall mortality (HR 1.71, 95% CI 0.21-14.0, p = 0.616). Conclusions: In patients with S-ICD, those who receive AS, in contrast to IAS, seem to have a worse prognosis. Large scale studies are needed to confirm this hypothesis and to explain this findings. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.413 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17093.xml