Outcomes and predictors of clinical response after upgrade to resynchronization therapy. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Outcomes and predictors of clinical response after upgrade to resynchronization therapy. (24th May 2021)
- Main Title:
- Outcomes and predictors of clinical response after upgrade to resynchronization therapy
- Authors:
- Brandao, M
Goncalves Almeida, J
Fonseca, P
Rosas, F
Santos, E
Ribeiro, J
Oliveira, M
Goncalves, H
Fontes-Carvalho, R
Primo, J - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. BACKGROUND: Upgrade to resynchronization therapy (CRT) is common practice in Europe. However, patient selection remains a challenge. Data regarding predictors of response to upgrade is currently lacking. AIM: To identify predictors of clinical response after upgrade to CRT. METHODS: Single-center retrospective study of consecutive patients submitted to upgrade to CRT (2007-2018). Patients underwent clinical and echocardiographic (echo) evaluation at baseline, 6-months and 1-year. Major adverse cardiac events (MACE) included hospitalization for heart failure (HF) or all-cause mortality. Clinical response was defined as New York Heart Association (NYHA) class improvement without MACE in the 1st year of follow-up (FU). Left ventricle end-systolic volume reduction of >15% designated echo response. Multivariate logistic regression was performed to identify predictors of clinical response to CRT. RESULTS: Fifty-six patients submitted to upgrade to CRT (80.4% male, mean age 70.0 ± 9.6 years) were included; 43 patients (78.2%) previously had a pacemaker and 12 (21.8%) had a defibrillator device. Most patients had non-ischemic HF (67.9%), with a mean baseline left ventricle (LV) ejection fraction of 27.9 ± 6.4%. Indications for upgrade were mainly pacemaker dependency or pacing-induced LV dysfunction (76.6%) and de novo left bundle branch block (23.4%). Thirty-one (59.3%) patients were clinical responders. MACEAbstract: Funding Acknowledgements: Type of funding sources: None. BACKGROUND: Upgrade to resynchronization therapy (CRT) is common practice in Europe. However, patient selection remains a challenge. Data regarding predictors of response to upgrade is currently lacking. AIM: To identify predictors of clinical response after upgrade to CRT. METHODS: Single-center retrospective study of consecutive patients submitted to upgrade to CRT (2007-2018). Patients underwent clinical and echocardiographic (echo) evaluation at baseline, 6-months and 1-year. Major adverse cardiac events (MACE) included hospitalization for heart failure (HF) or all-cause mortality. Clinical response was defined as New York Heart Association (NYHA) class improvement without MACE in the 1st year of follow-up (FU). Left ventricle end-systolic volume reduction of >15% designated echo response. Multivariate logistic regression was performed to identify predictors of clinical response to CRT. RESULTS: Fifty-six patients submitted to upgrade to CRT (80.4% male, mean age 70.0 ± 9.6 years) were included; 43 patients (78.2%) previously had a pacemaker and 12 (21.8%) had a defibrillator device. Most patients had non-ischemic HF (67.9%), with a mean baseline left ventricle (LV) ejection fraction of 27.9 ± 6.4%. Indications for upgrade were mainly pacemaker dependency or pacing-induced LV dysfunction (76.6%) and de novo left bundle branch block (23.4%). Thirty-one (59.3%) patients were clinical responders. MACE occurred in 37.5% of patients; 28.6% were hospitalized for HF and 13% died during the 1st year of FU. Clinical responders had a lower rate of atrial fibrillation (AF) (46.9% vs. 53.1%, p=.025) and a higher rate of pacemaker rythm prior to upgrade (80.6% vs 47.6%, p=.013). Among responders, the previous device was more frequently a pacemaker (87.5% vs 61.9%, p=.029), and the new device a CRT-P (81.2% vs 54.5%, p=.035). HF etiology did not differ between responders and non-responders. Multivariate analysis identified absence of AF (odds ratio [OR] 4.4, 95% confidence interval [CI] 1.1-17.6, p=.037), CRT-P (OR 5.7, 95% CI 1.3-25.8, p=.022) and quadripolar lead implant (OR 3.8, 95% CI 1.3-25.8, p=.024) as predictors of clinical response in upgraded patients. CONCLUSIONS: In this cohort, absence of AF, implantation of CRT-P and use of a quadripolar lead predicted clinical response to upgrade to CRT. Larger studies are warranted to tailor selection of patients for upgrade procedures. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.446 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17093.xml