Novel cryo-balloon ablation technology for pulmonary vein isolation in patients with atrial fibrillation: preliminary experience from a multicenter clinical practice. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Novel cryo-balloon ablation technology for pulmonary vein isolation in patients with atrial fibrillation: preliminary experience from a multicenter clinical practice. (24th May 2021)
- Main Title:
- Novel cryo-balloon ablation technology for pulmonary vein isolation in patients with atrial fibrillation: preliminary experience from a multicenter clinical practice
- Authors:
- Tondo, C
Stabile, G
Filannino, P
Moltrasio, M
De Simone, A
Artale, P
Fassini, G
La Rocca, V
Bianchi, S
Perna, F
Tundo, F
Colella, J
Iuliano, A
Malacrida, M
Iacopino, S - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Complete electrical pulmonary vein isolation (PVI) by cryo-balloon approach is a well-established ablation strategy of atrial fibrillation (AF). Recently, a new cryoablation system (POLARx) with unique features has been made available for clinical use. To date, no data exist on procedural characteristics of this system in a multicentric clinical practice. Purpose: We aimed to characterize the initial experience of this technology in the Italian clinical practice. Methods: Consecutive patients (pts) undergoing AF ablation from the CHARISMA registry at 5 Italian centres were included. Protocol-directed cryoablation was delivered for 180 sec or 240 sec according to operator's preference for isolation achieved in ≤60 sec, or 240 sec if isolation occurred >60 sec or when time to isolation (TTI) was not available. The ablation endpoint was PV isolation as assessed by entrance and exit block. Results: Two-hundred sixty-two cryoapplications from 49 pts (194 PVs) were analyzed. PVI was achieved with cryoablation only in all pts. The mean number of freeze applications per pt was 5.3 ± 1.5 (1.3 ± 0.6 for LIPV, LSPV and RSPV, 1.6 ± 1.3 for RIPV), with 143 (73.7%) PVs treated in a single-shot fashion (38, 19.6% with 2 shots; 13, 6.7% with more than 2 shots). Sixteen (33%) pts were treated with a single freeze to each of the PVs. The mean nadir temperature was -55.5 ± 6.9 °C and was colder than -50°C in 83% ofAbstract: Funding Acknowledgements: Type of funding sources: None. Background: Complete electrical pulmonary vein isolation (PVI) by cryo-balloon approach is a well-established ablation strategy of atrial fibrillation (AF). Recently, a new cryoablation system (POLARx) with unique features has been made available for clinical use. To date, no data exist on procedural characteristics of this system in a multicentric clinical practice. Purpose: We aimed to characterize the initial experience of this technology in the Italian clinical practice. Methods: Consecutive patients (pts) undergoing AF ablation from the CHARISMA registry at 5 Italian centres were included. Protocol-directed cryoablation was delivered for 180 sec or 240 sec according to operator's preference for isolation achieved in ≤60 sec, or 240 sec if isolation occurred >60 sec or when time to isolation (TTI) was not available. The ablation endpoint was PV isolation as assessed by entrance and exit block. Results: Two-hundred sixty-two cryoapplications from 49 pts (194 PVs) were analyzed. PVI was achieved with cryoablation only in all pts. The mean number of freeze applications per pt was 5.3 ± 1.5 (1.3 ± 0.6 for LIPV, LSPV and RSPV, 1.6 ± 1.3 for RIPV), with 143 (73.7%) PVs treated in a single-shot fashion (38, 19.6% with 2 shots; 13, 6.7% with more than 2 shots). Sixteen (33%) pts were treated with a single freeze to each of the PVs. The mean nadir temperature was -55.5 ± 6.9 °C and was colder than -50°C in 83% of the PVs. TTI information was evaluable in 120 (46%) cryoapplications with a median TTI of 47 [32-75] sec (median temperature at TTI = -49 [-53 to -42] °C). The mean time to target -40 °C (TTT) was 30.1 ± 6.9 sec with a TTT < 60 sec achieved in 99.2% of the cryoapplications; the mean thaw time to 0 °C was 18.6 ± 5.8 sec (thaw time >15 sec in 70.3% of the cryoapplications). The mean PV occlusion grade (rank 1-4) was 3.6 ± 0.6 (grade 2 in 5.2% of the cases, grade 3 in 25.6% and grade 4 in 69.2%). No complications were observed at 30 days post-procedure. Conclusion: In this first multicentric experience in a clinical practice setting, the novel cryo-balloon system proved to be safe and effective and resulted in a high proportion of successful single-freeze isolation. Cooling parameters seem to be slightly different from reference cryo-balloon technology. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.201 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17093.xml