Non-selective and selective His bundle pacing both preserve left ventricular activation time and pattern. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Non-selective and selective His bundle pacing both preserve left ventricular activation time and pattern. (24th May 2021)
- Main Title:
- Non-selective and selective His bundle pacing both preserve left ventricular activation time and pattern
- Authors:
- Arnold, A
Shun-Shin, MJ
Keene, D
Howard, JP
Chow, J
Miyazawa, AA
Qureshi, N
Lefroy, DC
Koa-Wing, M
Linton, NWF
Lim, PB
Peters, NS
Kanagaratnam, P
Francis, DP
Whinnett, ZI - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: Public Institution(s). Main funding source(s): British Heart Foundation Background: His bundle pacing can be achieved in two ways: selective His bundle pacing, where the His bundle is captured alone, and non-selective His bundle pacing, where local myocardium is also captured resulting a pre-excited ECG appearance. We assessed the impact of this ventricular pre-excitation on left and right ventricular dys-synchrony. Methods: We recruited patients who displayed both selective and non-selective His bundle pacing. We performed non-invasive epicardial electrical mapping to determine left and right ventricular activation times and patterns. Results: In the primary analysis (n = 20, all patients), non-selective His bundle pacing did not prolong LVAT compared to select His bundle pacing by a pre-specified non-inferiority margin of 10ms (LVAT prolongation: -5.5ms, 95% confidence interval (CI): -0.6 to -10.4, non-inferiority p < 0.0001). Non-selective His bundle pacing did not prolong right ventricular activation time (4.3ms, 95%CI: -4.0 to 12.8, p = 0.296) but did prolong QRS duration (22.1ms, 95%CI: 11.8 to 32.4, p = 0.0003). In patients with narrow intrinsic QRS (n = 6), non-selective His bundle pacing preserved left ventricular activation time (-2.9ms, 95%CI: -9.7 to 4.0, p = 0.331) but prolonged QRS duration (31.4ms, 95%CI: 22.0 to 40.7, p = 0.0003) and mean right ventricular activation time (16.8ms, 95%CI: -5.3 toAbstract: Funding Acknowledgements: Type of funding sources: Public Institution(s). Main funding source(s): British Heart Foundation Background: His bundle pacing can be achieved in two ways: selective His bundle pacing, where the His bundle is captured alone, and non-selective His bundle pacing, where local myocardium is also captured resulting a pre-excited ECG appearance. We assessed the impact of this ventricular pre-excitation on left and right ventricular dys-synchrony. Methods: We recruited patients who displayed both selective and non-selective His bundle pacing. We performed non-invasive epicardial electrical mapping to determine left and right ventricular activation times and patterns. Results: In the primary analysis (n = 20, all patients), non-selective His bundle pacing did not prolong LVAT compared to select His bundle pacing by a pre-specified non-inferiority margin of 10ms (LVAT prolongation: -5.5ms, 95% confidence interval (CI): -0.6 to -10.4, non-inferiority p < 0.0001). Non-selective His bundle pacing did not prolong right ventricular activation time (4.3ms, 95%CI: -4.0 to 12.8, p = 0.296) but did prolong QRS duration (22.1ms, 95%CI: 11.8 to 32.4, p = 0.0003). In patients with narrow intrinsic QRS (n = 6), non-selective His bundle pacing preserved left ventricular activation time (-2.9ms, 95%CI: -9.7 to 4.0, p = 0.331) but prolonged QRS duration (31.4ms, 95%CI: 22.0 to 40.7, p = 0.0003) and mean right ventricular activation time (16.8ms, 95%CI: -5.3 to 38.9, p = 0.108) compared to selective His bundle pacing. Activation pattern of the left ventricular surface was unchanged between selective and non-selective His bundle pacing. Non-selective His bundle pacing produced early basal right ventricular activation, which was not observed with selective His bundle pacing. Conclusions: Compared to selective His bundle pacing, local myocardial capture during non-selective His bundle pacing produces right ventricular pre-excitation resulting in prolongation of QRS duration. However, non-selective His bundle pacing preserves the left ventricular activation time and pattern of selective His bundle pacing. When choosing between selective and non-selective His bundle pacing, left ventricular dyssynchrony is not an important factor. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.379 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17091.xml