Accuracy of electroanatomical mapping guided cardiac radiotherapy for ventricular arrhytmias: pitfalls and solutions. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Accuracy of electroanatomical mapping guided cardiac radiotherapy for ventricular arrhytmias: pitfalls and solutions. (24th May 2021)
- Main Title:
- Accuracy of electroanatomical mapping guided cardiac radiotherapy for ventricular arrhytmias: pitfalls and solutions
- Authors:
- Abdel-Kafi, S
Sramko, M
Omara, S
De Riva, M
Cvek, IJ
Peichl, P
Kautzner, J
Zeppenfeld, K - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): This work was partially supported by the grant AZV NU20-02-00244 from the Ministry of Health of the Czech Republic OnBehalf: WECAM Background: One of the main limitations of Radiofrequency catheter ablation (RFCA) is the difficulty in targeting specific VT substrate locations when they are deep intramural, covered by epicardial fat or in the proximity of a coronary artery. Stereotactic body radiotherapy (SBRT) has emerged as an alternative treatment for VT after RFCA failure. However, the accuracy of substrate volume delineation, the gross target volume (GTV), based on electroanatomical mapping (EAM) and interobserver agreement are still unknown. Aim: To analyze and optimize the interobserver agreement for GTV delineation on cardiac CT (CCT) based on EAM data acquired to guide radiotherapy for ventricular arrhythmias. Method: Available EAM data was exported and merged with the segmented CCT using manual registration by two observers. A GTV was created by the observers for predefined left ventricular (LV) areas based on preselected endocardial EAM points, indicating the 2D-surface area of interest. The interobserver (non)overlapping GTV volumes were analyzed. The influence of (interobserver) registration accuracy and availability of EAM data on the final GTV and 2D-surface location within each LV area was evaluated. Results: The median distance betweenAbstract: Funding Acknowledgements: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): This work was partially supported by the grant AZV NU20-02-00244 from the Ministry of Health of the Czech Republic OnBehalf: WECAM Background: One of the main limitations of Radiofrequency catheter ablation (RFCA) is the difficulty in targeting specific VT substrate locations when they are deep intramural, covered by epicardial fat or in the proximity of a coronary artery. Stereotactic body radiotherapy (SBRT) has emerged as an alternative treatment for VT after RFCA failure. However, the accuracy of substrate volume delineation, the gross target volume (GTV), based on electroanatomical mapping (EAM) and interobserver agreement are still unknown. Aim: To analyze and optimize the interobserver agreement for GTV delineation on cardiac CT (CCT) based on EAM data acquired to guide radiotherapy for ventricular arrhythmias. Method: Available EAM data was exported and merged with the segmented CCT using manual registration by two observers. A GTV was created by the observers for predefined left ventricular (LV) areas based on preselected endocardial EAM points, indicating the 2D-surface area of interest. The interobserver (non)overlapping GTV volumes were analyzed. The influence of (interobserver) registration accuracy and availability of EAM data on the final GTV and 2D-surface location within each LV area was evaluated. Results: The median distance between the CCT and EAM after registration was 2.7 mm, 95%th percentile 6.2 mm for observer #1 and 3.0 mm, 95%th percentile 7.6 mm for observer #2 (p = 0.9). Created GTVs were significantly different (8 vs 19 ml) with lowest GTV overlap (35%) for lateral wall target areas. Similar, the highest shift between 2D-surfaces was observed for the lateral LV (6.4mm (3.0-9.9)). The same trend is seen in the (non) overlapping volume for lateral area (P = 0.004). The optimal surface registration accuracy (2.6 mm) and interobserver agreement (Δ interobserver EAM surface registration accuracy 1.32 mm) on final GTVs could be achieved if at least three cardiac chambers were mapped, including high-density LV EAM. Conclusion: Detailed EAM of at least three chambers allows for accurate co-registration of EAM data with CCT and high interobserver agreement on GTVs to guide radiotherapy of ventricular arrythmias. However, the substrate location should be taken in consideration when creating a treatment volume margin. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.345 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17091.xml