Pulmonary vein isolation by irreversible electroporation: an efficacy and safety study in 20 patients with atrial fibrillation. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Pulmonary vein isolation by irreversible electroporation: an efficacy and safety study in 20 patients with atrial fibrillation. (24th May 2021)
- Main Title:
- Pulmonary vein isolation by irreversible electroporation: an efficacy and safety study in 20 patients with atrial fibrillation
- Authors:
- Loh, P
Groen, MHA
Taha, K
Wittkampf, FHM
Doevendans, PA
Van Es, R - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: Private company. Main funding source(s): Abbott Background: Irreversible electroporation (IRE) is a promising new non-thermal ablation technology for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). First in human studies demonstrated the feasibility and safety of IRE PVI. Objective: Further investigate the safety of IRE PVI. Methods: Twenty patients with symptomatic AF underwent IRE PVI under conscious sedation. Oral anticoagulation was uninterrupted and heparin was administered to maintain activated clotting time at 300-350 seconds. Non-arcing, non-barotraumatic 6 ms, 200 J IRE applications were delivered via a custom non-steerable 8 F, 14-polar circular IRE ablation catheter with a variable hoop diameter (16-27 mm). Voltage mapping of the left atrium and the PVs was performed before and after ablation with a conventional circular mapping catheter. For both catheters a single transseptal access (8 F introducer, Agilis NxTTM) was used. Adenosine testing was performed after a 30-minute waiting period. On day 1 after ablation, patients underwent esophagoscopy and brain MRI (DWI/FLAIR). If abnormalities were detected, examinations were repeated in due time. Results: In 20 patients, all 80 PVs could be successfully isolated with a mean of 11, 8 ± 1, 4 IRE applications per patient. Average time from first to last IRE application was 22 ± 5 minutes, total procedure duration was 107 ± 13 minutesAbstract: Funding Acknowledgements: Type of funding sources: Private company. Main funding source(s): Abbott Background: Irreversible electroporation (IRE) is a promising new non-thermal ablation technology for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). First in human studies demonstrated the feasibility and safety of IRE PVI. Objective: Further investigate the safety of IRE PVI. Methods: Twenty patients with symptomatic AF underwent IRE PVI under conscious sedation. Oral anticoagulation was uninterrupted and heparin was administered to maintain activated clotting time at 300-350 seconds. Non-arcing, non-barotraumatic 6 ms, 200 J IRE applications were delivered via a custom non-steerable 8 F, 14-polar circular IRE ablation catheter with a variable hoop diameter (16-27 mm). Voltage mapping of the left atrium and the PVs was performed before and after ablation with a conventional circular mapping catheter. For both catheters a single transseptal access (8 F introducer, Agilis NxTTM) was used. Adenosine testing was performed after a 30-minute waiting period. On day 1 after ablation, patients underwent esophagoscopy and brain MRI (DWI/FLAIR). If abnormalities were detected, examinations were repeated in due time. Results: In 20 patients, all 80 PVs could be successfully isolated with a mean of 11, 8 ± 1, 4 IRE applications per patient. Average time from first to last IRE application was 22 ± 5 minutes, total procedure duration was 107 ± 13 minutes and total fluoroscopy time was 23 ± 5 minutes. One PV reconnection occurred during adenosine testing, re-isolation was achieved with 2 additional IRE pulses. No periprocedural complications were observed. Brain MRI on day 1 after ablation showed punctate asymptomatic lesions in 3/20 patients (15%). At follow-up MRI the lesion disappeared in 1 patient while in the other 2 patients 1 lesion persisted. Esophagoscopy on day 1 showed an asymptomatic esophageal lesion in 1/20 patients (5%), at repeat esophagoscopy on day 22 the lesion had resolved completely. Conclusion: Acute electrical PV isolation could be achieved safely and rapidly by IRE ablation under conscious sedation in 20 patients with symptomatic AF. Acute silent cerebral lesions were detected in 3/20 patients (15%) and may be due to ablation or to changes of therapeutic and diagnostic catheters over a single transseptal access. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.095 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17091.xml