Conduction disturbances after TAVR: rates of pacemaker implantation, burden of ventricular pacing and prognostic significance. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Conduction disturbances after TAVR: rates of pacemaker implantation, burden of ventricular pacing and prognostic significance. (24th May 2021)
- Main Title:
- Conduction disturbances after TAVR: rates of pacemaker implantation, burden of ventricular pacing and prognostic significance
- Authors:
- Bricoli, S
Benatti, G
Vignali, L
Tadonio, I
Notarangelo, MF
Crocamo, A
Gonzi, G
Placci, A
Bottoni, N
Biagi, A
Rossi, L
Guiducci, V
Losi, L
Zardini, M - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. BACKGROUND: The occurrence of conduction disturbances remains frequent after TAVR. However, the effect of PM on mortality is controversial and many patients may recover spontaneous AV conduction during follow-up. PURPOSE: To evaluate the incidence of PM implantation after TAVR, PM dependency and burden of ventricular pacing during follow-up and their influence on mortality. METHODS AND RESULTS: We performed a retrospective analysis of all consecutive 293 patients who underwent TAVR from 2015 to 2019 at our hospital, regional hub for this procedure. Patients were classified into 3 groups: patients without PM (no-PM), patients with a PM implanted prior to TAVR (pre-PM) and patients requiring a PM following TAVR (post-PM) and their clinical and procedural characteristics are listed in Table 1. The rate of PM implantation after TAVR was 20, 8%, at a median of 3.6 days after the procedure. The most common indication was complete AV block. A VVIR pacemaker was implanted in 28 patients, a DDD/DDDR PM in 27 patients and 2 patients received a CRT device. Among post-PPM patients, only 16% were PM-dependent at 2-month and 1-year follow-up. All of them received a PM for complete AV block (AVB). At 1-year follow-up, RV pacing burden was 60% among AVB patients and 23% in patients with a PM implanted for other reasons. PM implantation after TAVR was not associated with a mortality difference at 30-day, 1-year andAbstract: Funding Acknowledgements: Type of funding sources: None. BACKGROUND: The occurrence of conduction disturbances remains frequent after TAVR. However, the effect of PM on mortality is controversial and many patients may recover spontaneous AV conduction during follow-up. PURPOSE: To evaluate the incidence of PM implantation after TAVR, PM dependency and burden of ventricular pacing during follow-up and their influence on mortality. METHODS AND RESULTS: We performed a retrospective analysis of all consecutive 293 patients who underwent TAVR from 2015 to 2019 at our hospital, regional hub for this procedure. Patients were classified into 3 groups: patients without PM (no-PM), patients with a PM implanted prior to TAVR (pre-PM) and patients requiring a PM following TAVR (post-PM) and their clinical and procedural characteristics are listed in Table 1. The rate of PM implantation after TAVR was 20, 8%, at a median of 3.6 days after the procedure. The most common indication was complete AV block. A VVIR pacemaker was implanted in 28 patients, a DDD/DDDR PM in 27 patients and 2 patients received a CRT device. Among post-PPM patients, only 16% were PM-dependent at 2-month and 1-year follow-up. All of them received a PM for complete AV block (AVB). At 1-year follow-up, RV pacing burden was 60% among AVB patients and 23% in patients with a PM implanted for other reasons. PM implantation after TAVR was not associated with a mortality difference at 30-day, 1-year and long-term follow-up. Pre-PPM patients showed a higher mortality rate at long-term follow-up although not statistically significant. CONCLUSIONS: Our data suggest that a single chamber device should be preferred in patients implanted for reasons other than complete AVB; in patients with AVB, the use of dual chamber device with an algorithm to minimize RV pacing should be the most suitable choice. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.382 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17091.xml