Long term stability of the subcutaneous cardioverter defibrillator implanted by means of the intermuscular two incision technique. (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Long term stability of the subcutaneous cardioverter defibrillator implanted by means of the intermuscular two incision technique. (24th May 2021)
- Main Title:
- Long term stability of the subcutaneous cardioverter defibrillator implanted by means of the intermuscular two incision technique
- Authors:
- Bisignani, G
Bisignani, A
Cavaliere, AL
Lovecchio, M
Valsecchi, S
De Bonis, S - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background To ensure effective defibrillation with the subcutaneous implantable cardioverter defibrillator (S-ICD), both the lead and the generator must be adequately positioned extrathoracically. We assessed the long-term adequacy of the S-ICD system position and its stability in a group of patients who received the S-ICD by means of the two-incision intermuscular technique. Methods The PRAETORIAN score uses chest radiography to provide feedback on S-ICD positioning, and identifies patients with high defibrillation thresholds. We compared radiographs taken immediately after implantation and on 12-month follow-up examination. Results We analyzed data from 38 patients with the S-ICD generator positioned in an intermuscular pocket. The median PRAETORIAN score was 38 [25th to 75th percentile: 30 to 60]. Two (5%) patients had a score of 90 (intermediate risk of conversion failure). The thickness of the adipose tissue between the coil and the sternum was ≤1 coil width in 72% of patients, the generator was on, or posterior to, the midline in 94% of patients, and the amount of fat tissue between the generator and the thoracic wall was less than the generator width in 78% of patients. No generator or electrode dislodgments were detected on analyzing radiographs collected at the 12-month visit. In all patients, assessment of the PRAETORIAN score confirmed the values calculated on post-implantation analysis. DuringAbstract: Funding Acknowledgements: Type of funding sources: None. Background To ensure effective defibrillation with the subcutaneous implantable cardioverter defibrillator (S-ICD), both the lead and the generator must be adequately positioned extrathoracically. We assessed the long-term adequacy of the S-ICD system position and its stability in a group of patients who received the S-ICD by means of the two-incision intermuscular technique. Methods The PRAETORIAN score uses chest radiography to provide feedback on S-ICD positioning, and identifies patients with high defibrillation thresholds. We compared radiographs taken immediately after implantation and on 12-month follow-up examination. Results We analyzed data from 38 patients with the S-ICD generator positioned in an intermuscular pocket. The median PRAETORIAN score was 38 [25th to 75th percentile: 30 to 60]. Two (5%) patients had a score of 90 (intermediate risk of conversion failure). The thickness of the adipose tissue between the coil and the sternum was ≤1 coil width in 72% of patients, the generator was on, or posterior to, the midline in 94% of patients, and the amount of fat tissue between the generator and the thoracic wall was less than the generator width in 78% of patients. No generator or electrode dislodgments were detected on analyzing radiographs collected at the 12-month visit. In all patients, assessment of the PRAETORIAN score confirmed the values calculated on post-implantation analysis. During follow-up, no ineffective therapies, sudden cardiac or device-related deaths occurred. Conclusions The position of the S-ICD system implanted using the two-incision intermuscular technique was adequate at the time of implantation and remained stable after 12 months. … (more)
- Is Part Of:
- Europace. Volume 23:Supplement 3(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Supplement 3(2021)
- Issue Display:
- Volume 23, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2021-0023-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-24
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab116.403 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17090.xml