Reliability of the Electromechanical Delay Components Assessment during the Relaxation Phase. (6th March 2013)
- Record Type:
- Journal Article
- Title:
- Reliability of the Electromechanical Delay Components Assessment during the Relaxation Phase. (6th March 2013)
- Main Title:
- Reliability of the Electromechanical Delay Components Assessment during the Relaxation Phase
- Authors:
- Cè, Emiliano
Rampichini, Susanna
Limonta, Eloisa
Esposito, Fabio - Other Names:
- Perrey Stephane Academic Editor.
- Abstract:
- Abstract : The study aimed to assess by an electromyographic (EMG), mechanomyographic (MMG), and force-combined approach the electrochemical and mechanical components of the overall electromechanical delay during relaxation (R-EMD). Reliability of the measurements was also assessed. To this purpose, supramaximal tetanic stimulations (50 Hz) were delivered to the gastrocnemius medialis muscle of 17 participants. During stimulations, the EMG, MMG, and force signals were detected, and the time lag between EMG cessation and the beginning of force decay (Δ t EMG-F, as temporal indicators of the electrochemical events) and from the initial force decrease to the largest negative peak of MMG signal during relaxation (Δ t F-MMG, as temporal indicators of the mechanical events) was calculated, together with overall R-EMD duration (from EMG cessation to the largest MMG negative peak during relaxation). Peak force (pF), half relaxation time (HRT), and MMG peak-to-peak during the relaxation phase (R-MMG p-p) were also calculated. Test-retest reliability was assessed by Intraclass Correlation Coefficient (ICC). With a total R-EMD duration of 96.9 ± 1.9 ms, Δ t EMG-F contributed for about 24% (23.4 ± 2.7 ms) while Δ t F-MMG for about 76% (73.5 ± 3.2 ms). Reliability of the measurements was high for all variables. Our findings show that the main contributor to R-EMD is represented by the mechanical components (series elastic components and muscle fibres behaviour), with a high reliabilityAbstract : The study aimed to assess by an electromyographic (EMG), mechanomyographic (MMG), and force-combined approach the electrochemical and mechanical components of the overall electromechanical delay during relaxation (R-EMD). Reliability of the measurements was also assessed. To this purpose, supramaximal tetanic stimulations (50 Hz) were delivered to the gastrocnemius medialis muscle of 17 participants. During stimulations, the EMG, MMG, and force signals were detected, and the time lag between EMG cessation and the beginning of force decay (Δ t EMG-F, as temporal indicators of the electrochemical events) and from the initial force decrease to the largest negative peak of MMG signal during relaxation (Δ t F-MMG, as temporal indicators of the mechanical events) was calculated, together with overall R-EMD duration (from EMG cessation to the largest MMG negative peak during relaxation). Peak force (pF), half relaxation time (HRT), and MMG peak-to-peak during the relaxation phase (R-MMG p-p) were also calculated. Test-retest reliability was assessed by Intraclass Correlation Coefficient (ICC). With a total R-EMD duration of 96.9 ± 1.9 ms, Δ t EMG-F contributed for about 24% (23.4 ± 2.7 ms) while Δ t F-MMG for about 76% (73.5 ± 3.2 ms). Reliability of the measurements was high for all variables. Our findings show that the main contributor to R-EMD is represented by the mechanical components (series elastic components and muscle fibres behaviour), with a high reliability level for this type of approach. … (more)
- Is Part Of:
- Physiology journal. Volume 2013(2013)
- Journal:
- Physiology journal
- Issue:
- Volume 2013(2013)
- Issue Display:
- Volume 2013, Issue 2013 (2013)
- Year:
- 2013
- Volume:
- 2013
- Issue:
- 2013
- Issue Sort Value:
- 2013-2013-2013-0000
- Page Start:
- Page End:
- Publication Date:
- 2013-03-06
- Subjects:
- Physiology -- Periodicals
Physiological Phenomena
Physiology
Periodical
Fulltext
Internet Resource
Periodical
Periodicals
612 - Journal URLs:
- https://www.hindawi.com/journals/physiology/ ↗
- DOI:
- 10.1155/2013/517838 ↗
- Languages:
- English
- ISSNs:
- 2314-4300
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 17027.xml