Invasive and Ultrasound Based Monitoring of the Intracranial Pressure in an Experimental Model of Epidural Hematoma Progressing towards Brain Tamponade on Rabbits. (21st January 2014)
- Record Type:
- Journal Article
- Title:
- Invasive and Ultrasound Based Monitoring of the Intracranial Pressure in an Experimental Model of Epidural Hematoma Progressing towards Brain Tamponade on Rabbits. (21st January 2014)
- Main Title:
- Invasive and Ultrasound Based Monitoring of the Intracranial Pressure in an Experimental Model of Epidural Hematoma Progressing towards Brain Tamponade on Rabbits
- Authors:
- Kasapas, Konstantinos
Diamantopoulou, Angela
Pentilas, Nicolaos
Papalois, Apostolos
Douzinas, Emmanuel
Kouraklis, Gregorios
Slama, Michel
Terkawi, Abdullah Sulieman
Blaivas, Michael
Sargsyan, Ashot Ernest
Karakitsos, Dimitrios - Other Names:
- Morimatsu H. Academic Editor.
Paulson O. B. Academic Editor. - Abstract:
- Abstract : Introduction . An experimental epidural hematoma model was used to study the relation of ultrasound indices, namely, transcranial color-coded-Doppler (TCCD) derived pulsatility index (PI), optic nerve sheath diameter (ONSD), and pupil constriction velocity (V ) which was derived from a consensual sonographic pupillary light reflex (PLR) test with invasive intracranial pressure (ICP) measurements. Material and Methods . Twenty rabbits participated in the study. An intraparenchymal ICP catheter and a 5F Swan-Ganz catheter (SG) for the hematoma reproduction were used. We successively introduced 0.1 mL increments of autologous blood into the SG until the Cushing reaction occurred. Synchronous ICP and ultrasound measurements were performed accordingly. Results . A constant increase of PI and ONSD and a decrease of V values were observed with increased ICP values. The relationship between the ultrasound variables and ICP was exponential; thus curved prediction equations of ICP were used. PI, ONSD, and V were significantly correlated with ICP (r 2 = 0.84 ± 0.076, r 2 = 0.62 ± 0.119, and r 2 = 0.78 ± 0.09, resp. (all P < 0.001 )). Conclusion . Although statistically significant prediction models of ICP were derived from ultrasound indices, the exponential relationship between the parameters underpins that results should be interpreted with caution and in the current experimental context.
- Is Part Of:
- TheScientificWorldjournal. Volume 2014(2014)
- Journal:
- TheScientificWorldjournal
- Issue:
- Volume 2014(2014)
- Issue Display:
- Volume 2014, Issue 2014 (2014)
- Year:
- 2014
- Volume:
- 2014
- Issue:
- 2014
- Issue Sort Value:
- 2014-2014-2014-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-01-21
- Subjects:
- Science -- Periodicals
Technology -- Periodicals
Medicine -- Periodicals
505 - Journal URLs:
- https://www.hindawi.com/journals/tswj/biblio/ ↗
- DOI:
- 10.1155/2014/504248 ↗
- Languages:
- English
- ISSNs:
- 2356-6140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 17036.xml