Development of a Continuous Blood Pressure Measurement and Cardiovascular Multi-Indicator Platform for Asian Populations by Using a Back Propagation Neural Network and Dual Photoplethysmography Sensor Signal Acquisition Technology. (29th May 2021)
- Record Type:
- Journal Article
- Title:
- Development of a Continuous Blood Pressure Measurement and Cardiovascular Multi-Indicator Platform for Asian Populations by Using a Back Propagation Neural Network and Dual Photoplethysmography Sensor Signal Acquisition Technology. (29th May 2021)
- Main Title:
- Development of a Continuous Blood Pressure Measurement and Cardiovascular Multi-Indicator Platform for Asian Populations by Using a Back Propagation Neural Network and Dual Photoplethysmography Sensor Signal Acquisition Technology
- Authors:
- Yen, Chih-Ta
Chang, Sheng-Nan
Cai, Cheng-Yang - Other Names:
- Castano Victor M. Academic Editor.
- Abstract:
- Abstract : This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography (PPG) sensors and a back propagation neural network (BPNN) that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators. The proposed platform measured the signal changes in PPG and converted them into physiological indicators, such as pulse transit time (PTT), pulse wave velocity (PWV), perfusion index (PI), heart rate (HR), and pulse wave analysis (PWA); these indicators were then fed into the BPNN to calculate blood pressure. The hardware of the experiment comprised 2 PPG components (i.e., Raspberry Pi 3 Model B and analog-to-digital converter [MCP3008]), which were connected using a serial peripheral interface. The BPNN algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure (SBP) and diastolic blood pressure (DBP). To increase the robustness of the BPNN model, this study input data of 100 Asian participants into the training database, including those with and without cardiovascular disease, each with a proportion of approximately 50%. The experimental results revealed that the mean and standard deviation of SBP were 2.23 ± 2.24 mmHg, with a mean squared error of 3.15 mmHg. The mean and standard deviation of DBP was 3.5 ±Abstract : This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography (PPG) sensors and a back propagation neural network (BPNN) that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators. The proposed platform measured the signal changes in PPG and converted them into physiological indicators, such as pulse transit time (PTT), pulse wave velocity (PWV), perfusion index (PI), heart rate (HR), and pulse wave analysis (PWA); these indicators were then fed into the BPNN to calculate blood pressure. The hardware of the experiment comprised 2 PPG components (i.e., Raspberry Pi 3 Model B and analog-to-digital converter [MCP3008]), which were connected using a serial peripheral interface. The BPNN algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure (SBP) and diastolic blood pressure (DBP). To increase the robustness of the BPNN model, this study input data of 100 Asian participants into the training database, including those with and without cardiovascular disease, each with a proportion of approximately 50%. The experimental results revealed that the mean and standard deviation of SBP were 2.23 ± 2.24 mmHg, with a mean squared error of 3.15 mmHg. The mean and standard deviation of DBP was 3.5 ± 3.53 mmHg, with a mean squared error of 4.96 mmHg. The proposed real-time blood pressure measurement system exhibited a mean accuracy of 98.22% and 95.58% for SBP and DBP, respectively. … (more)
- Is Part Of:
- Journal of nanomaterials. Volume 2021(2021)
- Journal:
- Journal of nanomaterials
- Issue:
- Volume 2021(2021)
- Issue Display:
- Volume 2021, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 2021
- Issue:
- 2021
- Issue Sort Value:
- 2021-2021-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-29
- Subjects:
- Nanostructured materials -- Periodicals
Nanotechnology -- Periodicals
Nanomatériaux
Nanostructured materials
Nanotechnology
Nanostructures
Nanotechnology
Periodicals
Fulltext
Internet Resources
Periodicals
620.115 - Journal URLs:
- https://www.hindawi.com/journals/jnm/ ↗
http://www.hindawi.com/GetJournal.aspx?journal=JNM ↗ - DOI:
- 10.1155/2021/6613817 ↗
- Languages:
- English
- ISSNs:
- 1687-4110
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 17031.xml