Increasing the height of the anterior lip on a tibial insert in a posterior stabilized knee prosthesis has little effect on the wear rate. (May 2021)
- Record Type:
- Journal Article
- Title:
- Increasing the height of the anterior lip on a tibial insert in a posterior stabilized knee prosthesis has little effect on the wear rate. (May 2021)
- Main Title:
- Increasing the height of the anterior lip on a tibial insert in a posterior stabilized knee prosthesis has little effect on the wear rate
- Authors:
- Wang, Xiao-Hong
Bi, Zheng
Dong, Xiang
Hu, Sen-Yuan
Xu, Li-jun
Cheng, Cheng-Kung - Abstract:
- Highlights: Knee implants with different anterior lip heights have a similar wear rate during different daily activities. The location of maximum wear depth was similar among the three tibial inserts tested with different lip heights. The tibial insert with the highest lip showed slight anterior wear scaring due to anterior contact during swing phase. Abstract: A high anterior lip on a total knee prosthesis is an effective way of reducing anterior translation, but the effect on joint wear is unclear. Using finite element analysis (FEA), this study quantitatively compared wear rates and anterior contact stresses in three posterior stabilized knee prostheses with different heights for the anterior lip during six daily activities (walking, stair ascent, stair descent, sit-to-stand, pivot turn and crossover turn). The wear rate and location of maximum wear depth were similar for the three lip heights tested, but the knee with the highest anterior lip also showed slight anterior wear scaring due to articular contact stress during swing phase, which was highly dependent on the shape of the contact interface. This study illustrates that tibial inserts with a high anterior lip maintain a wear rate similar to moderate and low lip posterior stabilized designs.
- Is Part Of:
- Medical engineering & physics. Volume 91(2021)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 91(2021)
- Issue Display:
- Volume 91, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 91
- Issue:
- 2021
- Issue Sort Value:
- 2021-0091-2021-0000
- Page Start:
- 48
- Page End:
- 53
- Publication Date:
- 2021-05
- Subjects:
- Knee prosthesis -- High anterior lip -- Wear -- Contact stresses -- Finite element method
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2021.03.007 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17031.xml