Preparation of a New Copper/Mercury‐Based Amalgam Electrode with Minimal Mercury Content and Its Application for the Determination of Azathioprine in Biological Fluids. Issue 19 (22nd May 2021)
- Record Type:
- Journal Article
- Title:
- Preparation of a New Copper/Mercury‐Based Amalgam Electrode with Minimal Mercury Content and Its Application for the Determination of Azathioprine in Biological Fluids. Issue 19 (22nd May 2021)
- Main Title:
- Preparation of a New Copper/Mercury‐Based Amalgam Electrode with Minimal Mercury Content and Its Application for the Determination of Azathioprine in Biological Fluids
- Authors:
- Alizadeh, Taher
Shojaeianfar, Moslem
Reza Ganjali, Mohammad - Abstract:
- Abstract: Herein, a new copper/mercury‐based amalgam electrode with 45 wt % copper was introduced. An amalgam electrode with the lowest mercury content among all amalgam electrodes, reported so far, was introduced. The method of making and activating the electrode was investigated and the working conditions were established. The as‐prepared electrode was employed to determine azathioprine(Aza) using differential pulse adsorptive stripping voltammetry (DPASV) method. The required factors were considered for the electrode voltammetric response to evaluate and optimize Aza level. The proper response of this electrode was obtained in Brinton‐Robinson buffer(BRB) (pH 2) at −0.15 V for 200 seconds. The electrode response to the target compound was linear in the concentration range from 0.04 to 1.0 μM. The detection limit was found to be about 1.6×10 −8 M. The relative standard deviation (RSD) for 5 determinations was obtained to be about 3.5 % (the average of RSDs calculated for all concentrations, represented in the calibration curve). The method was successfully applied for Aza determination in plasma and urine samples which led to satisfactory results. It can be concluded that the presence of high levels of potential interfering agents such as ascorbic acid and cysteine did not affect the Aza determination. Abstract : By mixing mercury and copper physically, the amalgam is produced. Manufactured amalgam can be converted to electrode by taking a little time to complete theAbstract: Herein, a new copper/mercury‐based amalgam electrode with 45 wt % copper was introduced. An amalgam electrode with the lowest mercury content among all amalgam electrodes, reported so far, was introduced. The method of making and activating the electrode was investigated and the working conditions were established. The as‐prepared electrode was employed to determine azathioprine(Aza) using differential pulse adsorptive stripping voltammetry (DPASV) method. The required factors were considered for the electrode voltammetric response to evaluate and optimize Aza level. The proper response of this electrode was obtained in Brinton‐Robinson buffer(BRB) (pH 2) at −0.15 V for 200 seconds. The electrode response to the target compound was linear in the concentration range from 0.04 to 1.0 μM. The detection limit was found to be about 1.6×10 −8 M. The relative standard deviation (RSD) for 5 determinations was obtained to be about 3.5 % (the average of RSDs calculated for all concentrations, represented in the calibration curve). The method was successfully applied for Aza determination in plasma and urine samples which led to satisfactory results. It can be concluded that the presence of high levels of potential interfering agents such as ascorbic acid and cysteine did not affect the Aza determination. Abstract : By mixing mercury and copper physically, the amalgam is produced. Manufactured amalgam can be converted to electrode by taking a little time to complete the solidification process and then powdering as before. or, at the beginning, while the amalgam is a paste, compresses it into a tube and then giving time to solidify and polish at the end, the electrode is prepared. The electrode produced from the paste amalgam was used to determine azathioprine. … (more)
- Is Part Of:
- ChemistrySelect. Volume 6:Issue 19(2021)
- Journal:
- ChemistrySelect
- Issue:
- Volume 6:Issue 19(2021)
- Issue Display:
- Volume 6, Issue 19 (2021)
- Year:
- 2021
- Volume:
- 6
- Issue:
- 19
- Issue Sort Value:
- 2021-0006-0019-0000
- Page Start:
- 4791
- Page End:
- 4796
- Publication Date:
- 2021-05-22
- Subjects:
- Amalgam electrode -- Azathioprine -- Copper -- differential pulse adsorptive stripping voltammetry
Chemistry -- Periodicals
540.5 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2365-6549 ↗ - DOI:
- 10.1002/slct.202000546 ↗
- Languages:
- English
- ISSNs:
- 2365-6549
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.241000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17020.xml