Development and external validation of prediction models to predict implantable cardioverter-defibrillator efficacy in primary prevention of sudden cardiac death. Issue 6 (14th February 2021)
- Record Type:
- Journal Article
- Title:
- Development and external validation of prediction models to predict implantable cardioverter-defibrillator efficacy in primary prevention of sudden cardiac death. Issue 6 (14th February 2021)
- Main Title:
- Development and external validation of prediction models to predict implantable cardioverter-defibrillator efficacy in primary prevention of sudden cardiac death
- Authors:
- Verstraelen, Tom E
van Barreveld, Marit
van Dessel, Pascal H F M
Boersma, Lucas V A
Delnoy, Peter-Paul P H M
Tuinenburg, Anton E
Theuns, Dominic A M J
van der Voort, Pepijn H
Kimman, Gerardus P
Buskens, Erik
Hulleman, Michiel
Allaart, Cornelis P
Strikwerda, Sipke
Scholten, Marcoen F
Meine, Mathias
Abels, René
Maass, Alexander H
Firouzi, Mehran
Widdershoven, Jos W M G
Elders, Jan
van Gent, Marco W F
Khan, Muchtiar
Vernooy, Kevin
Grauss, Robert W
Tukkie, Raymond
van Erven, Lieselot
Spierenburg, Han A M
Brouwer, Marc A
Bartels, Gerard L
Bijsterveld, Nick R
Borger van der Burg, Alida E
Vet, Mattheus W
Derksen, Richard
Knops, Reinoud E
Bracke, Frank A L E
Harden, Markus
Sticherling, Christian
Willems, Rik
Friede, Tim
Zabel, Markus
Dijkgraaf, Marcel G W
Zwinderman, Aeilko H
Wilde, Arthur A M
… (more) - Abstract:
- Abstract: Aims: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. Methods and results: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1–2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0–3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. Conclusion: Although thisAbstract: Aims: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. Methods and results: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1–2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0–3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. Conclusion: Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed. … (more)
- Is Part Of:
- Europace. Volume 23:Issue 6(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Issue 6(2021)
- Issue Display:
- Volume 23, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 6
- Issue Sort Value:
- 2021-0023-0006-0000
- Page Start:
- 887
- Page End:
- 897
- Publication Date:
- 2021-02-14
- Subjects:
- Implantable cardioverter-defibrillator -- Primary prevention -- Risk factors -- Mortality -- Sudden cardiac death -- Prediction models
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab012 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16998.xml