Role of the rabbit whole-heart model for electrophysiologic safety pharmacology of non-cardiovascular drugs. Issue 6 (17th November 2020)
- Record Type:
- Journal Article
- Title:
- Role of the rabbit whole-heart model for electrophysiologic safety pharmacology of non-cardiovascular drugs. Issue 6 (17th November 2020)
- Main Title:
- Role of the rabbit whole-heart model for electrophysiologic safety pharmacology of non-cardiovascular drugs
- Authors:
- Ellermann, Christian
Wolfes, Julian
Eckardt, Lars
Frommeyer, Gerrit - Abstract:
- Abstract: Plenty of non-cardiovascular drugs alter cardiac electrophysiology and may ultimately lead to life-threatening arrhythmias. In clinical practice, measuring the QT interval as a marker for the repolarization period is the most common tool to assess the electrophysiologic safety of drugs. However, the sole measurement of the QT interval may be insufficient to determine the proarrhythmic risk of non-cardiovascular agents. Several other markers are considered in pre-clinical safety testing to determine potential harm on cardiac electrophysiology. Besides measuring typical electrophysiologic parameters such as repolarization duration, whole-heart models allow the determination of potential predictors for proarrhythmia. Spatial and temporal heterogeneity as well as changes of shape of the action potential can be easily assessed. In addition, provocation manoeuvers (either by electrolyte imbalances or programmed pacing protocols) may induce sustained arrhythmias and thereby determine ventricular vulnerability to arrhythmias. Compared with the human heart, the rabbit heart possesses a similar distribution of ion currents that govern cardiac repolarization, resulting in a rectangular action potential configuration in both species. In addition, similar biophysical properties of rabbit and human cardiac ion channels lead to a comparable pharmacologic response in human and rabbit hearts. Of note, arrhythmia patterns resemble in both species due to the similar effective size ofAbstract: Plenty of non-cardiovascular drugs alter cardiac electrophysiology and may ultimately lead to life-threatening arrhythmias. In clinical practice, measuring the QT interval as a marker for the repolarization period is the most common tool to assess the electrophysiologic safety of drugs. However, the sole measurement of the QT interval may be insufficient to determine the proarrhythmic risk of non-cardiovascular agents. Several other markers are considered in pre-clinical safety testing to determine potential harm on cardiac electrophysiology. Besides measuring typical electrophysiologic parameters such as repolarization duration, whole-heart models allow the determination of potential predictors for proarrhythmia. Spatial and temporal heterogeneity as well as changes of shape of the action potential can be easily assessed. In addition, provocation manoeuvers (either by electrolyte imbalances or programmed pacing protocols) may induce sustained arrhythmias and thereby determine ventricular vulnerability to arrhythmias. Compared with the human heart, the rabbit heart possesses a similar distribution of ion currents that govern cardiac repolarization, resulting in a rectangular action potential configuration in both species. In addition, similar biophysical properties of rabbit and human cardiac ion channels lead to a comparable pharmacologic response in human and rabbit hearts. Of note, arrhythmia patterns resemble in both species due to the similar effective size of human and rabbit hearts. Thus, the rabbit heart is particularly suitable for testing the electrophysiologic safety of drugs. Several experimental setups have been developed for studying cardiac electrophysiology in rabbits, ranging from single cell to tissue preparations, whole-heart setups, and in vivo models. … (more)
- Is Part Of:
- Europace. Volume 23:Issue 6(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Issue 6(2021)
- Issue Display:
- Volume 23, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 6
- Issue Sort Value:
- 2021-0023-0006-0000
- Page Start:
- 828
- Page End:
- 836
- Publication Date:
- 2020-11-17
- Subjects:
- Drug safety -- QT interval -- Torsade de pointes -- Long QT syndrome -- Rabbit -- Langendorff -- Whole-heart model -- Electrophysiological safety -- Pharmacology
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa288 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16998.xml