Procedural efficiencies, lesion metrics, and 12-month clinical outcomes for Ablation Index-guided 50 W ablation for atrial fibrillation. Issue 6 (6th March 2021)
- Record Type:
- Journal Article
- Title:
- Procedural efficiencies, lesion metrics, and 12-month clinical outcomes for Ablation Index-guided 50 W ablation for atrial fibrillation. Issue 6 (6th March 2021)
- Main Title:
- Procedural efficiencies, lesion metrics, and 12-month clinical outcomes for Ablation Index-guided 50 W ablation for atrial fibrillation
- Authors:
- O'Brien, Jim
Obeidat, Mohammed
Kozhuharov, Nikola
Ding, Wern Yew
Tovmassian, Lilith
Bierme, Cedric
Chin, Shui Hao
Chu, Gavin S
Luther, Vishal
Snowdon, Richard L
Gupta, Dhiraj - Abstract:
- Abstract: Aims: The safety of Ablation Index (AI)-guided 50 W ablation for atrial fibrillation (AF) remains uncertain, and mid-term clinical outcomes have not been described. The interplay between AI and its components at 50 W has not been reported. Methods and results: Eighty-eight consecutive AF patients (44% paroxysmal) underwent AI-guided 50 W ablation. Procedural and 12-month clinical outcomes were compared with 93 consecutive controls (65% paroxysmal) who underwent AI-guided ablation using 35–40 W. Posterior wall isolation (PWI) was performed in 44 (50%) and 23 (25%) patients in the 50 and 35–40 W groups, respectively, P < 0.001. The last 10 patients from each group underwent analysis of individual lesions ( n = 1230) to explore relationships between different powers and the AI components. Pulmonary vein isolation was successful in all patients. Posterior wall isolation was successful in 41/44 (93.2%) and 22/23 (95.7%) in the 50 and 35–40 W groups, respectively ( P = 0.685). Radiofrequency times (20 vs. 26 min, P < 0.001) and total procedure times (130 vs. 156 min, P = 0.002) were significantly lower in the 50 W group. No complication or steam pop was seen in either group. Twelve-month freedom from arrhythmia was similar (80.2% vs. 82.8%, P = 0.918). A higher proportion of lesions in the 50 W group were associated with impedance drop >7 Ω (54.6% vs. 45.5%, P < 0.001). Excessive ablation (AI >600 anteriorly, >500 posteriorly) was more frequent in the 50 W groupAbstract: Aims: The safety of Ablation Index (AI)-guided 50 W ablation for atrial fibrillation (AF) remains uncertain, and mid-term clinical outcomes have not been described. The interplay between AI and its components at 50 W has not been reported. Methods and results: Eighty-eight consecutive AF patients (44% paroxysmal) underwent AI-guided 50 W ablation. Procedural and 12-month clinical outcomes were compared with 93 consecutive controls (65% paroxysmal) who underwent AI-guided ablation using 35–40 W. Posterior wall isolation (PWI) was performed in 44 (50%) and 23 (25%) patients in the 50 and 35–40 W groups, respectively, P < 0.001. The last 10 patients from each group underwent analysis of individual lesions ( n = 1230) to explore relationships between different powers and the AI components. Pulmonary vein isolation was successful in all patients. Posterior wall isolation was successful in 41/44 (93.2%) and 22/23 (95.7%) in the 50 and 35–40 W groups, respectively ( P = 0.685). Radiofrequency times (20 vs. 26 min, P < 0.001) and total procedure times (130 vs. 156 min, P = 0.002) were significantly lower in the 50 W group. No complication or steam pop was seen in either group. Twelve-month freedom from arrhythmia was similar (80.2% vs. 82.8%, P = 0.918). A higher proportion of lesions in the 50 W group were associated with impedance drop >7 Ω (54.6% vs. 45.5%, P < 0.001). Excessive ablation (AI >600 anteriorly, >500 posteriorly) was more frequent in the 50 W group (9.7% vs. 4.3%, P < 0.001). Conclusion: Ablation Index-guided 50 W AF ablation is as safe and effective as lower powers and results in reduced ablation and procedure times. Radiofrequency lesions are more likely to be therapeutic, but there is a higher risk of delivering excessive ablation. … (more)
- Is Part Of:
- Europace. Volume 23:Issue 6(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Issue 6(2021)
- Issue Display:
- Volume 23, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 6
- Issue Sort Value:
- 2021-0023-0006-0000
- Page Start:
- 878
- Page End:
- 886
- Publication Date:
- 2021-03-06
- Subjects:
- Atrial fibrillation -- Radiofrequency -- 50 W -- Ablation Index -- Contact force -- Impedance
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab031 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16998.xml