Behavior of an air-cooled thermosiphon during a non-air gas ingress event. (August 2021)
- Record Type:
- Journal Article
- Title:
- Behavior of an air-cooled thermosiphon during a non-air gas ingress event. (August 2021)
- Main Title:
- Behavior of an air-cooled thermosiphon during a non-air gas ingress event
- Authors:
- Lisowski, Darius
Kraus, Adam
Lv, Qiuping
Hu, Rui - Abstract:
- Highlights: The transient response of heavy gas ingress on an air-cooled thermosiphon was studied. The experiment design and procedure were carefully controlled for only gas species. Deterioration of natural circulation occurred during an 18-minute period of system flow stagnation. CFD simulations were performed to provide insight into the underlying physical phenomena. Abstract: This study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1, 200 cu-feet of the heavy gas, twice theHighlights: The transient response of heavy gas ingress on an air-cooled thermosiphon was studied. The experiment design and procedure were carefully controlled for only gas species. Deterioration of natural circulation occurred during an 18-minute period of system flow stagnation. CFD simulations were performed to provide insight into the underlying physical phenomena. Abstract: This study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1, 200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior. … (more)
- Is Part Of:
- International journal of heat and mass transfer. Volume 175(2021)
- Journal:
- International journal of heat and mass transfer
- Issue:
- Volume 175(2021)
- Issue Display:
- Volume 175, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 175
- Issue:
- 2021
- Issue Sort Value:
- 2021-0175-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Natural circulation -- Thermosiphon -- Gas ingress -- Passive safety
Heat -- Transmission -- Periodicals
Mass transfer -- Periodicals
Chaleur -- Transmission -- Périodiques
Transfert de masse -- Périodiques
Electronic journals
621.4022 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00179310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijheatmasstransfer.2021.121155 ↗
- Languages:
- English
- ISSNs:
- 0017-9310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.280000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16996.xml