Investigating centering, scan length, and arm position impact on radiation dose across 4 countries from 4 continents during pandemic: Mitigating key radioprotection issues. (April 2021)
- Record Type:
- Journal Article
- Title:
- Investigating centering, scan length, and arm position impact on radiation dose across 4 countries from 4 continents during pandemic: Mitigating key radioprotection issues. (April 2021)
- Main Title:
- Investigating centering, scan length, and arm position impact on radiation dose across 4 countries from 4 continents during pandemic: Mitigating key radioprotection issues
- Authors:
- Ebrahimian, Shadi
Oliveira Bernardo, Monica
Alberto Moscatelli, Antônio
Tapajos, Juliana
Leitão Tapajós, Luciano
Jamil Khoury, Helen
Babaei, Rosa
Karimi Mobin, Hadi
Mohseni, Iman
Arru, Chiara
Carriero, Alessandro
Falaschi, Zeno
Pasche, Alessio
Saba, Luca
Homayounieh, Fatemeh
Bizzo, Bernardo C.
Vassileva, Jenia
Kalra, Mannudeep K. - Abstract:
- Highlights: Mis-centering and over-scanning on chest CT are frequent in patients with COVID-19. Patients with arms by side are more likely to be mis-centered and over-scanned. Mis-centering and over-scanning are associated with higher radiation doses. Abstract: Purpose: Optimization of CT scan practices can help achieve and maintain optimal radiation protection. The aim was to assess centering, scan length, and positioning of patients undergoing chest CT for suspected or known COVID-19 pneumonia and to investigate their effect on associated radiation doses. Methods: With respective approvals from institutional review boards, we compiled CT imaging and radiation dose data from four hospitals belonging to four countries (Brazil, Iran, Italy, and USA) on 400 adult patients who underwent chest CT for suspected or known COVID-19 pneumonia between April 2020 and August 2020. We recorded patient demographics and volume CT dose index (CTDIvol ) and dose length product (DLP). From thin-section CT images of each patient, we estimated the scan length and recorded the first and last vertebral bodies at the scan start and end locations. Patient mis-centering and arm position were recorded. Data were analyzed with analysis of variance (ANOVA). Results: The extent and frequency of patient mis-centering did not differ across the four CT facilities (>0.09). The frequency of patients scanned with arms by their side (11–40% relative to those with arms up) had greater mis-centering and higherHighlights: Mis-centering and over-scanning on chest CT are frequent in patients with COVID-19. Patients with arms by side are more likely to be mis-centered and over-scanned. Mis-centering and over-scanning are associated with higher radiation doses. Abstract: Purpose: Optimization of CT scan practices can help achieve and maintain optimal radiation protection. The aim was to assess centering, scan length, and positioning of patients undergoing chest CT for suspected or known COVID-19 pneumonia and to investigate their effect on associated radiation doses. Methods: With respective approvals from institutional review boards, we compiled CT imaging and radiation dose data from four hospitals belonging to four countries (Brazil, Iran, Italy, and USA) on 400 adult patients who underwent chest CT for suspected or known COVID-19 pneumonia between April 2020 and August 2020. We recorded patient demographics and volume CT dose index (CTDIvol ) and dose length product (DLP). From thin-section CT images of each patient, we estimated the scan length and recorded the first and last vertebral bodies at the scan start and end locations. Patient mis-centering and arm position were recorded. Data were analyzed with analysis of variance (ANOVA). Results: The extent and frequency of patient mis-centering did not differ across the four CT facilities (>0.09). The frequency of patients scanned with arms by their side (11–40% relative to those with arms up) had greater mis-centering and higher CTDIvol and DLP at 2/4 facilities (p = 0.027–0.05). Despite lack of variations in effective diameters (p = 0.14), there were significantly variations in scan lengths, CTDIvol and DLP across the four facilities (p < 0.001). Conclusions: Mis-centering, over-scanning, and arms by the side are frequent issues with use of chest CT in COVID-19 pneumonia and are associated with higher radiation doses. … (more)
- Is Part Of:
- Physica medica. Volume 84(2021)
- Journal:
- Physica medica
- Issue:
- Volume 84(2021)
- Issue Display:
- Volume 84, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 84
- Issue:
- 2021
- Issue Sort Value:
- 2021-0084-2021-0000
- Page Start:
- 125
- Page End:
- 131
- Publication Date:
- 2021-04
- Subjects:
- CT -- Radiation dose -- Patient mis-centering -- Patient position -- Radiation protection
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.04.001 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16995.xml