National indication-based diagnostic reference level values in computed tomography: Preliminary results from Ghana. (April 2021)
- Record Type:
- Journal Article
- Title:
- National indication-based diagnostic reference level values in computed tomography: Preliminary results from Ghana. (April 2021)
- Main Title:
- National indication-based diagnostic reference level values in computed tomography: Preliminary results from Ghana
- Authors:
- Botwe, Benard Ohene
Schandorf, Cyril
Inkoom, Stephen
Faanu, Augustine
Rolstadaas, Linn
Goa, Pål Erik - Abstract:
- Highlights: In Ghana there are no established national indication-based diagnostic reference levels. First national indication-based diagnostic reference levels have been developed. The developed diagnostic reference levels are recommended to be used to manage dose in Ghana. Abstract: Purpose: This study was conducted to develop national indication-based DRL values for common indications of adult computed tomography (CT) examinations for clinical application in Ghana. Materials and methods: The methodological approach recommended by the International Commission on Radiological Protection (ICRP), Publication 135, for the development of DRLs, was employed. Studies on CT infrastructure, common indications and quality control tests were first undertaken. A sample of 20 CT dose descriptor/quantity data sets were collected from each centre for each indication. Overall, 3960 data sets were collected for all identified common indications from 71.4% of the total CT scanners in Ghana (25/35). The data were collected from image folders reported and accepted by radiologists. The objective image quality was assessed through a signal to noise ratio (SNR) analysis prior to using the data and extracting DRL values. Results: Clinical indications and their respective DRL values in terms of volume weighted CT dose index (CTDIvol ) and dose length product (DLP) were cerebrovascular accident (CVA)/stroke (77 mGy; 1313 mGy.cm), head trauma/injury (76 mGy; 1596 mGy.cm), brain tumour/spaceHighlights: In Ghana there are no established national indication-based diagnostic reference levels. First national indication-based diagnostic reference levels have been developed. The developed diagnostic reference levels are recommended to be used to manage dose in Ghana. Abstract: Purpose: This study was conducted to develop national indication-based DRL values for common indications of adult computed tomography (CT) examinations for clinical application in Ghana. Materials and methods: The methodological approach recommended by the International Commission on Radiological Protection (ICRP), Publication 135, for the development of DRLs, was employed. Studies on CT infrastructure, common indications and quality control tests were first undertaken. A sample of 20 CT dose descriptor/quantity data sets were collected from each centre for each indication. Overall, 3960 data sets were collected for all identified common indications from 71.4% of the total CT scanners in Ghana (25/35). The data were collected from image folders reported and accepted by radiologists. The objective image quality was assessed through a signal to noise ratio (SNR) analysis prior to using the data and extracting DRL values. Results: Clinical indications and their respective DRL values in terms of volume weighted CT dose index (CTDIvol ) and dose length product (DLP) were cerebrovascular accident (CVA)/stroke (77 mGy; 1313 mGy.cm), head trauma/injury (76 mGy; 1596 mGy.cm), brain tumour/space occupying lesion (SOL) (77 mGy; 2696 mGy.cm), lung tumour/cancer (12 mGy; 828 mGy.cm) and chest lesion with chronic kidney disease (CKD) (13 mGy; 467 mGy.cm). Others were abdominopelvic lesion (17 mGy; 1299 mGy.cm), kidney stones (15 mGy; 731 mGy.cm), urothelial malignancy/CT-intravenous urogram (CT-IVU) (11 mGy; 1449 mGy.cm) and pulmonary embolism (PE) (14 mGy; 942 mGy.cm). Conclusion: National Indication-based DRL values developed in this study are recommended to be used to manage CT radiation dose in Ghana. … (more)
- Is Part Of:
- Physica medica. Volume 84(2021)
- Journal:
- Physica medica
- Issue:
- Volume 84(2021)
- Issue Display:
- Volume 84, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 84
- Issue:
- 2021
- Issue Sort Value:
- 2021-0084-2021-0000
- Page Start:
- 274
- Page End:
- 284
- Publication Date:
- 2021-04
- Subjects:
- Diagnostic Reference Levels (DRLs) -- Optimisation -- Computed tomography -- Indication-based DRLs -- Ghana
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.03.012 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16995.xml