Radiomics classifier to quantify automatic segmentation quality of cardiac sub-structures for radiotherapy treatment planning. (March 2021)
- Record Type:
- Journal Article
- Title:
- Radiomics classifier to quantify automatic segmentation quality of cardiac sub-structures for radiotherapy treatment planning. (March 2021)
- Main Title:
- Radiomics classifier to quantify automatic segmentation quality of cardiac sub-structures for radiotherapy treatment planning
- Authors:
- Maffei, Nicola
Manco, Luigi
Aluisio, Giovanni
D'Angelo, Elisa
Ferrazza, Patrizia
Vanoni, Valentina
Meduri, Bruno
Lohr, Frank
Guidi, Gabriele - Abstract:
- Highlights: Radiomics features comparison between manual and automatic segmentation. Artificial Intelligence Classifier implemented to assess segmentation quality. Decision tree supports clinical workflow for automatic atlas database expansion. Abstract: Purpose: A radiomics features classifier was implemented to evaluate segmentation quality of heart structures. A robust feature set sensitive to incorrect contouring would provide an ideal quantitative index to drive autocontouring optimization. Methods: Twenty-five cardiac sub-structures were contoured as regions of interest in 36 CTs. Radiomic features were extracted from manually-contoured (MC) and Hierarchical-Clustering automatic-contouring (AC) structures. A robust feature-set was identified from correctly contoured CT datasets. Features variation was analyzed over a MC/AC dataset. A supervised-learning approach was used to train an Artificial-Intelligence (AI) classifier; incorrect contouring cases were generated from the gold-standard MC datasets with translations, expansions and contractions. ROC curves and confusion matrices were used to evaluate the AI-classifier performance. Results: Twenty radiomics features, were found to be robust across structures, showing a good/excellent intra-class correlation coefficient (ICC) index comparing MC/AC. A significant correlation was obtained with quantitative indexes (Dice-Index, Hausdorff-distance). The trained AI-classifier detected correct contours (CC) and not correctHighlights: Radiomics features comparison between manual and automatic segmentation. Artificial Intelligence Classifier implemented to assess segmentation quality. Decision tree supports clinical workflow for automatic atlas database expansion. Abstract: Purpose: A radiomics features classifier was implemented to evaluate segmentation quality of heart structures. A robust feature set sensitive to incorrect contouring would provide an ideal quantitative index to drive autocontouring optimization. Methods: Twenty-five cardiac sub-structures were contoured as regions of interest in 36 CTs. Radiomic features were extracted from manually-contoured (MC) and Hierarchical-Clustering automatic-contouring (AC) structures. A robust feature-set was identified from correctly contoured CT datasets. Features variation was analyzed over a MC/AC dataset. A supervised-learning approach was used to train an Artificial-Intelligence (AI) classifier; incorrect contouring cases were generated from the gold-standard MC datasets with translations, expansions and contractions. ROC curves and confusion matrices were used to evaluate the AI-classifier performance. Results: Twenty radiomics features, were found to be robust across structures, showing a good/excellent intra-class correlation coefficient (ICC) index comparing MC/AC. A significant correlation was obtained with quantitative indexes (Dice-Index, Hausdorff-distance). The trained AI-classifier detected correct contours (CC) and not correct contours (NCC) with an accuracy of 82.6% and AUC of 0.91. True positive rate (TPR) was 85.1% and 81.3% for CC and NCC. Detection of NCC at this point of the development still depended strongly on degree of contouring imperfection. Conclusions: A set of radiomics features, robust on "gold-standard" contour and sensitive to incorrect contouring was identified and implemented in an AI-workflow to quantify segmentation accuracy. This workflow permits an automatic assessment of segmentation quality and may accelerate expansion of an existing autocontouring atlas database as well as improve dosimetric analyses of large treatment plan databases. … (more)
- Is Part Of:
- Physica medica. Volume 83(2021)
- Journal:
- Physica medica
- Issue:
- Volume 83(2021)
- Issue Display:
- Volume 83, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 83
- Issue:
- 2021
- Issue Sort Value:
- 2021-0083-2021-0000
- Page Start:
- 278
- Page End:
- 286
- Publication Date:
- 2021-03
- Subjects:
- Artificial intelligence -- Automatic segmentation -- Radiomics -- Cardiac structures
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.05.009 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16978.xml