Safety and effectiveness of the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease: SPARTA, a multicenter experience. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Safety and effectiveness of the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease: SPARTA, a multicenter experience. Issue 1 (January 2020)
- Main Title:
- Safety and effectiveness of the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease
- Authors:
- Montefusco, Antonio
De Filippo, Ovidio
Gili, Sebastiano
Mancone, Massimo
Calcagno, Simone
Cirillo, Plinio
Esposito, Giovanni
Poli, Arnaldo
Ferrara, Erika
Smolka, Grzegorz
Wanha, Wojciech
Palmieri, Cataldo
Pastormerlo, Luigi Emilio
Baumbach, Andreas
Sganzerla, Paolo
Tamburino, Corrado
Bruno, Francesco
Secco, Gioel Gabrio
Nicolino, Annamaria
Yew, Kuang Leon
di Palma, Gaetano
Wojakowski, Wojciech
Sardella, Gennaro
Rinaldi, Mauro
Cortese, Bernardo
D'Ascenzo, Fabrizio - Abstract:
- Abstract : Aims: To assess the long-term outcomes of patients treated with sirolimus-eluting Stentys stent in a real-life setting. Background: Few data regarding the safety and effectiveness of self-apposing sirolimus-eluting Stentys stent are available. Methods: 278 patients (30% stable coronary artery disease, 70% acute coronary syndromes, and 54% on unprotected left main) treated with sirolimus eluting Stentys stent were retrospectively included in the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease multicenter registry. Major adverse cardiovascular events (MACE, a composite of cardiac death, myocardial infarction, target lesion revascularization, stent thrombosis) were the primary end-point, single components of MACE were the secondary ones. Results: After 13 months (interquartile range 5–32), MACE was 14%. Stent thrombosis occurred in 3.9% of the patients (2.5% definite stent thrombosis and 1.4% probable stent thrombosis), 66% of them presenting with ST-segment elevation myocardial infarction (STEMI) at admission. Cardiovascular death, target lesion revascularization and myocardial infarction was 4.7%, 8.3%, and 7.2%, respectively. At multivariate analysis, risk of MACE was increased by diabetes (hazard ratios 4.76; P = 0.002) but was not affected by the indication leading to sirolimus-eluting Stentys stent implantation (marked vessel tapering vs. coronary ecstasies, hazard ratios 0.74, P = 0.71). Conclusion:Abstract : Aims: To assess the long-term outcomes of patients treated with sirolimus-eluting Stentys stent in a real-life setting. Background: Few data regarding the safety and effectiveness of self-apposing sirolimus-eluting Stentys stent are available. Methods: 278 patients (30% stable coronary artery disease, 70% acute coronary syndromes, and 54% on unprotected left main) treated with sirolimus eluting Stentys stent were retrospectively included in the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease multicenter registry. Major adverse cardiovascular events (MACE, a composite of cardiac death, myocardial infarction, target lesion revascularization, stent thrombosis) were the primary end-point, single components of MACE were the secondary ones. Results: After 13 months (interquartile range 5–32), MACE was 14%. Stent thrombosis occurred in 3.9% of the patients (2.5% definite stent thrombosis and 1.4% probable stent thrombosis), 66% of them presenting with ST-segment elevation myocardial infarction (STEMI) at admission. Cardiovascular death, target lesion revascularization and myocardial infarction was 4.7%, 8.3%, and 7.2%, respectively. At multivariate analysis, risk of MACE was increased by diabetes (hazard ratios 4.76; P = 0.002) but was not affected by the indication leading to sirolimus-eluting Stentys stent implantation (marked vessel tapering vs. coronary ecstasies, hazard ratios 0.74, P = 0.71). Conclusion: Sirolimus-eluting Stentys stent may represent a potential solution for specific coronary anatomies such as bifurcation, ectasic, or tapered vessels. Risk of stent thrombosis appears related to clinical presentation with STEMI and to anatomic features, stressing the importance of the use of intracoronary imaging for self-expandable stents implantation. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Coronary artery disease. Volume 31:Issue 1(2020:Jan.)
- Journal:
- Coronary artery disease
- Issue:
- Volume 31:Issue 1(2020:Jan.)
- Issue Display:
- Volume 31, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 1
- Issue Sort Value:
- 2020-0031-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- drug-eluting stent -- percutaneous coronary intervention -- self-expandable stent
Coronary heart disease -- Periodicals
Coronary Disease -- Indexes
Coronary Disease -- Periodicals
616.123005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00019501-000000000-00000 ↗
http://www.coronary-artery.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MCA.0000000000000790 ↗
- Languages:
- English
- ISSNs:
- 0954-6928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3472.049000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16968.xml