Usefulness of High Resolution T2-Weighted Images in the Evaluation and Surveillance of Vestibular Schwannomas? Is Gadolinium Needed?. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Usefulness of High Resolution T2-Weighted Images in the Evaluation and Surveillance of Vestibular Schwannomas? Is Gadolinium Needed?. Issue 1 (January 2020)
- Main Title:
- Usefulness of High Resolution T2-Weighted Images in the Evaluation and Surveillance of Vestibular Schwannomas? Is Gadolinium Needed?
- Authors:
- Pizzini, Francesca B.
Sarno, Alessandro
Galazzo, Ilaria Boscolo
Fiorino, Francesco
Aragno, Anna M. R.
Ciceri, Elisa
Ghimenton, Claudio
Mansueto, Giancarlo - Abstract:
- Abstract : Objectives: First aim of study was to compare the diagnostic accuracy of high resolution T2-WI (HRT2-WI) and gadolinium-enhanced T1-weighted image (Gd T1-WI) sequences in quantitative evaluation of vestibular schwannomas (VS). The second one was to determine through qualitative evaluation when Gd-injection should be recommended. Methods: Two observers in consensus retrospectively reviewed 137 magnetic resonance imaging (MRI) scans of patients with histological diagnosis of VS (33 women, 26 men), 116 with both HRT2-WI and Gd T1-WI. The examinations were subdivided in: surveillance (10), pretreatment (30), posttreatment (43), and posttreatment follow-up (33) studies. Quantitative evaluation was based on size measurement of the lesion. Structural details of the lesion, facial nerve course, and involvement of the fundus of the internal auditory canal were assessed for the qualitative evaluation in both sequences. Results: No statistically significant changes were demonstrated between size measurement in the HRT2-WI and Gd T1-WI ( p = 0.329). Sensitivity, specificity, and accuracy of HRT2-WI in the detection of lesional size were 90.4, 98.9, 92.5%, respectively. HRT2-WI was worse for characterization of structural details in pretreatment, posttreatment, and posttreatment follow-up examinations. HRT2-WI showed better or equal capability for all the groups in the demonstration of the facial nerve course. In the evaluation of the involvement of the fundus of the internalAbstract : Objectives: First aim of study was to compare the diagnostic accuracy of high resolution T2-WI (HRT2-WI) and gadolinium-enhanced T1-weighted image (Gd T1-WI) sequences in quantitative evaluation of vestibular schwannomas (VS). The second one was to determine through qualitative evaluation when Gd-injection should be recommended. Methods: Two observers in consensus retrospectively reviewed 137 magnetic resonance imaging (MRI) scans of patients with histological diagnosis of VS (33 women, 26 men), 116 with both HRT2-WI and Gd T1-WI. The examinations were subdivided in: surveillance (10), pretreatment (30), posttreatment (43), and posttreatment follow-up (33) studies. Quantitative evaluation was based on size measurement of the lesion. Structural details of the lesion, facial nerve course, and involvement of the fundus of the internal auditory canal were assessed for the qualitative evaluation in both sequences. Results: No statistically significant changes were demonstrated between size measurement in the HRT2-WI and Gd T1-WI ( p = 0.329). Sensitivity, specificity, and accuracy of HRT2-WI in the detection of lesional size were 90.4, 98.9, 92.5%, respectively. HRT2-WI was worse for characterization of structural details in pretreatment, posttreatment, and posttreatment follow-up examinations. HRT2-WI showed better or equal capability for all the groups in the demonstration of the facial nerve course. In the evaluation of the involvement of the fundus of the internal auditory canal, HRT2-WI showed worse results or had a complementary role for the posttreatment and posttreatment follow-up groups, while in the other groups was considered mainly equal or complementary. Only in the surveillance group, HRT2-WI was never worse for all the criteria. Conclusion: Results for quantitative evaluation were similar in both the sequences. Gadolinium injection can be avoided only in surveillance studies. … (more)
- Is Part Of:
- Otology & neurotology. Volume 41:Issue 1(2020)
- Journal:
- Otology & neurotology
- Issue:
- Volume 41:Issue 1(2020)
- Issue Display:
- Volume 41, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2020-0041-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- Acoustic neuroma -- Contrast enhancement -- Magnetic resonance imaging
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000002436 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16973.xml