Validity of the wall goniometer as a screening tool to detect postural abnormalities in Parkinson's disease. (December 2019)
- Record Type:
- Journal Article
- Title:
- Validity of the wall goniometer as a screening tool to detect postural abnormalities in Parkinson's disease. (December 2019)
- Main Title:
- Validity of the wall goniometer as a screening tool to detect postural abnormalities in Parkinson's disease
- Authors:
- Tinazzi, Michele
Gandolfi, Marialuisa
Artusi, Carlo Alberto
Lanzafame, Ruggero
Zanolin, Elisabetta
Ceravolo, Roberto
Capecci, Marianna
Andrenelli, Elisa
Ceravolo, Maria Gabriella
Bonanni, Laura
Onofrj, Marco
Telese, Roberta
Bertolotti, Claudio
Polverino, Paola
Manganotti, Paolo
Mazzucchi, Sonia
Giannoni, Sara
Vacca, Laura
Stocchi, Fabrizio
Casali, Miriam
Zibetti, Maurizio
Lopiano, Leonardo
Fasano, Alfonso
Geroin, Christian - Abstract:
- Abstract: Introduction: Software-based measurements of postural abnormalities in Parkinson's disease (PD) are the gold standard but may be time-consuming and not always feasible in clinical practice. Wall goniometer (WG) is an easier, quicker, and inexpensive instrument for screening patients with postural abnormalities, but no studies have investigated its validity so far. The aim of this study was to investigate the validity of the WG to measure postural abnormalities. Methods: A total of 283 consecutive PD outpatients with ≥5° forward trunk, lateral trunk or forward neck bending (FTB, LTB, FNB, respectively) were recruited from seven centers for movement disorders. Postural abnormalities were measured in lateral and posterior view using a freeware program (gold standard) and the WG. Both angles were expressed in degrees (°). Sensitivity and specificity for the diagnosis of camptocormia, Pisa syndrome, and anterocollis were assessed. Results: WG showed good to excellent agreement (intraclass correlation coefficient from 0.80 to 0.98) compared to the gold standard. Bland-Altman plots showed a mean difference between the methods from −7.4° to 0.4° with limits of agreements from −17.7° to 9.5°. Sensitivity was 100% for the diagnosis of Pisa syndrome, 95.74% for anterocollis, 76.67% for upper camptocormia, and 63.64% for lower camptocormia. Specificity was 59.57% for Pisa syndrome, 71.43% for anterocollis, 89.80% for upper camptocormia, and 100% for lower camptocormia.Abstract: Introduction: Software-based measurements of postural abnormalities in Parkinson's disease (PD) are the gold standard but may be time-consuming and not always feasible in clinical practice. Wall goniometer (WG) is an easier, quicker, and inexpensive instrument for screening patients with postural abnormalities, but no studies have investigated its validity so far. The aim of this study was to investigate the validity of the WG to measure postural abnormalities. Methods: A total of 283 consecutive PD outpatients with ≥5° forward trunk, lateral trunk or forward neck bending (FTB, LTB, FNB, respectively) were recruited from seven centers for movement disorders. Postural abnormalities were measured in lateral and posterior view using a freeware program (gold standard) and the WG. Both angles were expressed in degrees (°). Sensitivity and specificity for the diagnosis of camptocormia, Pisa syndrome, and anterocollis were assessed. Results: WG showed good to excellent agreement (intraclass correlation coefficient from 0.80 to 0.98) compared to the gold standard. Bland-Altman plots showed a mean difference between the methods from −7.4° to 0.4° with limits of agreements from −17.7° to 9.5°. Sensitivity was 100% for the diagnosis of Pisa syndrome, 95.74% for anterocollis, 76.67% for upper camptocormia, and 63.64% for lower camptocormia. Specificity was 59.57% for Pisa syndrome, 71.43% for anterocollis, 89.80% for upper camptocormia, and 100% for lower camptocormia. Overall, the WG underestimated measurements, especially in lower camptocormia with an average of −8.7° (90% of cases). Conclusion: WG is a valid tool for screening Pisa syndrome and anterocollis, but approximately 10° more should be added for camptocormia. Highlights: WG showed good to excellent agreement as compared with the gold standard. WG has an excellent sensitivity for screening of Pisa syndrome and anterocollis. WG underestimated the measures of upper camptocormia by −6.1° on average. WG underestimated the measures of lower camptocormia by −8.7°on average. Approximately 10° more should be added when measuring camptocormia. … (more)
- Is Part Of:
- Parkinsonism & related disorders. Volume 69(2019)
- Journal:
- Parkinsonism & related disorders
- Issue:
- Volume 69(2019)
- Issue Display:
- Volume 69, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 69
- Issue:
- 2019
- Issue Sort Value:
- 2019-0069-2019-0000
- Page Start:
- 159
- Page End:
- 165
- Publication Date:
- 2019-12
- Subjects:
- Movement disorders -- Parkinsonism -- Bent spine syndrome -- Angle measurement -- Posture
Parkinson's disease -- Periodicals
Movement disorders -- Periodicals
Movement Disorders -- Periodicals
Nerve Degeneration -- Periodicals
Nervous System Diseases -- Periodicals
Parkinson Disease -- Periodicals
Tremor -- Periodicals
Parkinson, Maladie de -- Périodiques
Parkinson's disease
616.833 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13538020 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13538020 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13538020 ↗
http://www.prd-journal.com/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.parkreldis.2019.10.024 ↗
- Languages:
- English
- ISSNs:
- 1353-8020
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6406.787000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16975.xml