A novel software platform for volumetric assessment of ablation completeness. (1st January 2019)
- Record Type:
- Journal Article
- Title:
- A novel software platform for volumetric assessment of ablation completeness. (1st January 2019)
- Main Title:
- A novel software platform for volumetric assessment of ablation completeness
- Authors:
- Solbiati, Marco
Muglia, Riccardo
Goldberg, S. Nahum
Ierace, Tiziana
Rotilio, Alessandro
Passera, Katia M
Marre, Ilaria
Solbiati, Luigi - Abstract:
- Abstract: Purpose: To retrospectively evaluate the accuracy of a novel software platform for assessing completeness of percutaneous thermal ablations. Materials & methods: Ninety hepatocellular carcinomas (HCCs) in 50 patients receiving percutaneous ultrasound-guided microwave ablation (MWA) that resulted in apparent technical success at 24-h post-ablation computed tomography (CT) and with ≥1-year imaging follow-up were randomly selected from a 320 HCC ablation database (2010–2016). Using a novel volumetric registration software, pre-ablation CT volumes of the HCCs without and with the addition of a 5 mm safety margin, and corresponding post-ablation necrosis volumes were segmented, co-registered and overlapped. These were compared to visual side-by-side inspection of axial images. Results: At 1-year follow-up, CT showed absence of local tumor progression (LTP) in 69/90 (76.7%) cases and LTP in 21/90 (23.3%). For HCCs classified by the software as "incomplete tumor treatments", LTP developed in 13/17 (76.5%) and all 13 (100%) of these LTPs occurred exactly where residual non-ablated tumor was identified by retrospective software analysis. HCCs classified as "complete ablation with <100% 5 mm ablative margins" had LTP in 8/49 (16.3%), while none of 24 HCCs with "complete ablation including 100% 5 mm ablative margins" had LTP. Differences in LTP between both partially ablated HCCs vs completely ablated HCCs, and ablated HCCs with <100% vs with 100% 5 mm margins wereAbstract: Purpose: To retrospectively evaluate the accuracy of a novel software platform for assessing completeness of percutaneous thermal ablations. Materials & methods: Ninety hepatocellular carcinomas (HCCs) in 50 patients receiving percutaneous ultrasound-guided microwave ablation (MWA) that resulted in apparent technical success at 24-h post-ablation computed tomography (CT) and with ≥1-year imaging follow-up were randomly selected from a 320 HCC ablation database (2010–2016). Using a novel volumetric registration software, pre-ablation CT volumes of the HCCs without and with the addition of a 5 mm safety margin, and corresponding post-ablation necrosis volumes were segmented, co-registered and overlapped. These were compared to visual side-by-side inspection of axial images. Results: At 1-year follow-up, CT showed absence of local tumor progression (LTP) in 69/90 (76.7%) cases and LTP in 21/90 (23.3%). For HCCs classified by the software as "incomplete tumor treatments", LTP developed in 13/17 (76.5%) and all 13 (100%) of these LTPs occurred exactly where residual non-ablated tumor was identified by retrospective software analysis. HCCs classified as "complete ablation with <100% 5 mm ablative margins" had LTP in 8/49 (16.3%), while none of 24 HCCs with "complete ablation including 100% 5 mm ablative margins" had LTP. Differences in LTP between both partially ablated HCCs vs completely ablated HCCs, and ablated HCCs with <100% vs with 100% 5 mm margins were statistically significant ( p < .0001 and p = .036, respectively). Thus, 13/21 (61.9%) incomplete tumor treatments could have been detected immediately, were the software available at the time of ablation. Conclusions: A novel software platform for volumetric assessment of ablation completeness may increase the detection of incompletely ablated tumors, thereby holding the potential to avoid subsequent recurrences. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 36:Number 1(2019)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 36:Number 1(2019)
- Issue Display:
- Volume 36, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2019-0036-0001-0000
- Page Start:
- 336
- Page End:
- 342
- Publication Date:
- 2019-01-01
- Subjects:
- CT -- 3D rendering -- software -- image processing -- ablation
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2019.1569267 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16976.xml