Particulate generation with different oxygen delivery devices. (May 2021)
- Record Type:
- Journal Article
- Title:
- Particulate generation with different oxygen delivery devices. (May 2021)
- Main Title:
- Particulate generation with different oxygen delivery devices
- Authors:
- Helgeson, Scott A.
Lee, Augustine S.
Lim, Kaiser G.
Niven, Alexander S.
Patel, Neal M. - Abstract:
- Abstract: Background: The Coronavirus pandemic has a high mortality rate in patients that are mechanically ventilated, which has led to an ever increasing interest in noninvasive forms of oxygenation. The use of these devices has the theoretical risk of increased exposure risk because of possible particulate generation. This study aimed to quantify the particulate generation associated with different oxygen devices. Methods: This was a prospective single center study conducted during September 2020 using ten healthy adult volunteers. Testing was conducted in a negative pressure hospital room using a light scattering particle counter. The oxygen devices used were a nasal cannula, an OxyMask™, a non-rebreathing mask, and a high flow system. Particle measurements were obtained at baseline in the room and then with each oxygen delivery device and pre-specified oxygen flow rates. These measurements were obtained different distances from the volunteer with their mouth open. A Wilcoxon/Kruskal-Wallis test was performed on each separate oxygen modality with all flow rates as one model. Results: The particle concentrations were slightly non-significantly increased with the OxyMask™ and non-rebreathing mask at the closest distance measured. As the distance increased, these counts decreased closer to ambient levels. The nasal cannula and high flow nasal cannula particle counts were not significantly different from ambient measurements at either distance. Conclusion: Nasal cannula,Abstract: Background: The Coronavirus pandemic has a high mortality rate in patients that are mechanically ventilated, which has led to an ever increasing interest in noninvasive forms of oxygenation. The use of these devices has the theoretical risk of increased exposure risk because of possible particulate generation. This study aimed to quantify the particulate generation associated with different oxygen devices. Methods: This was a prospective single center study conducted during September 2020 using ten healthy adult volunteers. Testing was conducted in a negative pressure hospital room using a light scattering particle counter. The oxygen devices used were a nasal cannula, an OxyMask™, a non-rebreathing mask, and a high flow system. Particle measurements were obtained at baseline in the room and then with each oxygen delivery device and pre-specified oxygen flow rates. These measurements were obtained different distances from the volunteer with their mouth open. A Wilcoxon/Kruskal-Wallis test was performed on each separate oxygen modality with all flow rates as one model. Results: The particle concentrations were slightly non-significantly increased with the OxyMask™ and non-rebreathing mask at the closest distance measured. As the distance increased, these counts decreased closer to ambient levels. The nasal cannula and high flow nasal cannula particle counts were not significantly different from ambient measurements at either distance. Conclusion: Nasal cannula, OxyMask™, non-rebreathing mask, and high flow oxygen did not generate any additional aerosols or droplets above a baseline room measurement, but further studies are necessary to determine infectious risk. Highlights: There is a theoretical risk of particulate exposure when using noninvasive forms of oxygenation. Nasal cannula, OxyMask™, and high flow oxygen showed no difference in particulate generation over background counts. The detection of particulates remained consistent with varying distances from the patient's face. … (more)
- Is Part Of:
- Respiratory medicine. Volume 181(2021)
- Journal:
- Respiratory medicine
- Issue:
- Volume 181(2021)
- Issue Display:
- Volume 181, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 181
- Issue:
- 2021
- Issue Sort Value:
- 2021-0181-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05
- Subjects:
- Aerosol -- Droplets -- Particle generation -- Particle measurement -- Coronavirus -- High flow oxygen
Chest -- Diseases -- Periodicals
Chest -- Diseases -- Great Britain -- Periodicals
Respiratory organs -- Diseases -- Periodicals
Respiratory Tract Diseases -- Periodicals
Appareil respiratoire -- Maladies -- Périodiques
Thorax -- Maladies -- Périodiques
Appareil respiratoire -- Maladies -- Traitement -- Périodiques
Electronic journals
616.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09546111 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09546111 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09546111 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.rmed.2021.106386 ↗
- Languages:
- English
- ISSNs:
- 0954-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7777.661900
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16953.xml