Cook, Jonathan Alistair - Abstract:
- Abstract : Objective: To appraise studies reporting on clinical effectiveness and safety of surgical meshes used to augment rotator cuff repairs (RCRs). Design: Systematic review and meta-analysis. Data sources: MEDLINE, Embase and Cochrane databases were searched between April 2006 and April 2020. Eligibility criteria: All studies evaluating adults (≥18 years) undergoing RCR were considered. There were no language restrictions. Data extraction and synthesis: Screening, data extraction and quality appraisal were conducted by two independent reviewers. Meta-analysis was conducted using a random-effects models if ≥2 comparative studies reported the same outcome measure. Risk of bias assessment was undertaken for randomised (RoB2, Cochrane) and comparative studies (ROBINS-I, Cochrane). Results: We included 60 studies, consisting of 7 randomised controlled trials, 13 observational comparative studies and 40 observational case series. All comparative studies reported on shoulder-specific functional outcome scores, 18 on the radiographic occurrence of re-tear and 14 on pain score metrics. All studies contained some risk of bias. Compared with non-augmented repair, a small improvement in shoulder-specific function or pain scores was observed for synthetic patches with a mean improvement of 6.7 points on the University of California Los Angles (UCLA) shoulder score (95% CI 0.1 to 13.4) and 0.46 point reduction on the Visual Analogue Scale (95% CI −0.74 to −0.17), respectively. AAbstract : Objective: To appraise studies reporting on clinical effectiveness and safety of surgical meshes used to augment rotator cuff repairs (RCRs). Design: Systematic review and meta-analysis. Data sources: MEDLINE, Embase and Cochrane databases were searched between April 2006 and April 2020. Eligibility criteria: All studies evaluating adults (≥18 years) undergoing RCR were considered. There were no language restrictions. Data extraction and synthesis: Screening, data extraction and quality appraisal were conducted by two independent reviewers. Meta-analysis was conducted using a random-effects models if ≥2 comparative studies reported the same outcome measure. Risk of bias assessment was undertaken for randomised (RoB2, Cochrane) and comparative studies (ROBINS-I, Cochrane). Results: We included 60 studies, consisting of 7 randomised controlled trials, 13 observational comparative studies and 40 observational case series. All comparative studies reported on shoulder-specific functional outcome scores, 18 on the radiographic occurrence of re-tear and 14 on pain score metrics. All studies contained some risk of bias. Compared with non-augmented repair, a small improvement in shoulder-specific function or pain scores was observed for synthetic patches with a mean improvement of 6.7 points on the University of California Los Angles (UCLA) shoulder score (95% CI 0.1 to 13.4) and 0.46 point reduction on the Visual Analogue Scale (95% CI −0.74 to −0.17), respectively. A reduced likelihood of radiologically observed re-tear was observed for synthetic (risk ratio (RR) 0.41, 95% CI 0.27 to 0.61) and allograft (RR 0.34, 95% CI 0.18 to 0.65) patches. A total of 49 studies reported on the occurrence of complications. Slightly higher crude complication rates were observed following patch-augmented repair (2.1%) than standard repair (1.6%). Conclusions: While several studies suggest a decreased failure rate and small improvements in shoulder function and pain following augmented RCR, a paucity of rigorous clinical evaluation, for both effectiveness and safety, prevents firm recommendations. Prospero registration number: CRD42017057908. … (more)
- Is Part Of:
- BMJ open. Volume 10:Issue 12(2020)
- Journal:
- BMJ open
- Issue:
- Volume 10:Issue 12(2020)
- Issue Display:
- Volume 10, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 10
- Issue:
- 12
- Issue Sort Value:
- 2020-0010-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12-07
- Subjects:
- orthopaedic & trauma surgery -- adverse events -- biotechnology & bioinformatics
Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2020-039552 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16943.xml