Predictive Factors of the Adherence to Real-Time Continuous Glucose Monitoring Sensors: A Prospective Observational Study (PARCS STUDY). (September 2021)
- Record Type:
- Journal Article
- Title:
- Predictive Factors of the Adherence to Real-Time Continuous Glucose Monitoring Sensors: A Prospective Observational Study (PARCS STUDY). (September 2021)
- Main Title:
- Predictive Factors of the Adherence to Real-Time Continuous Glucose Monitoring Sensors: A Prospective Observational Study (PARCS STUDY)
- Authors:
- Murata, Takashi
Kuroda, Akio
Matsuhisa, Munehide
Toyoda, Masao
Kimura, Moritsugu
Hirota, Yushi
Kato, Ken
Sawaki, Hideaki
Tone, Atsuhito
Kawashima, Satoshi
Okada, Akira
Watanabe, Tomokazu
Nirengi, Shinsuke
Suganuma, Akiko
Sakane, Naoki - Abstract:
- Background: Information about factors related to better adherence to continuous glucose monitoring (CGM) sensor adherence is quite limited. Materials and Methods: Forty-six participants with type 1 diabetes using continuous subcutaneous insulin infusion (CSII) without CGM were recruited. The participants' characteristics and diabetes-related quality of life (QOL) were evaluated at baseline and one year after starting to use CGM. Participants wearing the sensor for ≥60% of the time were considered as adherent. Results: The mean age of the 46 participants was 44.1 ± 15.0 years old and the mean glycohemoglobin (HbA1c) was 7.7 ± 1.0%; 60.9% of the participants were classified as adherent. The duration of using CSII was longer in the adherent group, and the degree of diabetic retinopathy was significantly different. There were no significant differences in age, frequency of self-monitoring of blood glucose, or Hypoglycemia Fear Survey (HFS-B for behavior, HFS-W for worry) score at baseline between the adherent and nonadherent groups. The Problem Areas in Diabetes (PAID) score at baseline was significantly higher and the total CSII-QOL score at baseline was significantly lower in the adherent group. The usage of dual-wave bolus was significantly increased in the adherent group (34.6%-61.5%, P = .016), but not in the nonadherent group (33.3%-33.3%, P > .999). The HbA1c level showed a significant improvement in the adherent group (7.8%-7.3%, P < .001), but not in the nonadherentBackground: Information about factors related to better adherence to continuous glucose monitoring (CGM) sensor adherence is quite limited. Materials and Methods: Forty-six participants with type 1 diabetes using continuous subcutaneous insulin infusion (CSII) without CGM were recruited. The participants' characteristics and diabetes-related quality of life (QOL) were evaluated at baseline and one year after starting to use CGM. Participants wearing the sensor for ≥60% of the time were considered as adherent. Results: The mean age of the 46 participants was 44.1 ± 15.0 years old and the mean glycohemoglobin (HbA1c) was 7.7 ± 1.0%; 60.9% of the participants were classified as adherent. The duration of using CSII was longer in the adherent group, and the degree of diabetic retinopathy was significantly different. There were no significant differences in age, frequency of self-monitoring of blood glucose, or Hypoglycemia Fear Survey (HFS-B for behavior, HFS-W for worry) score at baseline between the adherent and nonadherent groups. The Problem Areas in Diabetes (PAID) score at baseline was significantly higher and the total CSII-QOL score at baseline was significantly lower in the adherent group. The usage of dual-wave bolus was significantly increased in the adherent group (34.6%-61.5%, P = .016), but not in the nonadherent group (33.3%-33.3%, P > .999). The HbA1c level showed a significant improvement in the adherent group (7.8%-7.3%, P < .001), but not in the nonadherent group (7.5%-7.2%, P = .102). Conclusions: Higher adherence to CGM sensors may be associated with a heavier emotional burden of diabetes and a worse QOL in relation to CSII at baseline. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 15:Number 5(2021)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 15:Number 5(2021)
- Issue Display:
- Volume 15, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 15
- Issue:
- 5
- Issue Sort Value:
- 2021-0015-0005-0000
- Page Start:
- 1084
- Page End:
- 1092
- Publication Date:
- 2021-09
- Subjects:
- adherence -- CGM -- CSII -- HFS -- PAID -- QOL
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296820939204 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16936.xml